Discrete-time PMSM Current Control Based on Current Measurement Error

Since permanent magnet synchronous machine (PMSM) control based on zero-order hold (ZOH) discretization can achieve better performance under low carrier ratio, it has attracted widespread attention from both academia and industry. However, due to its complex structure and the involvement of exponential calculations, the discrete-time current control difficultly conduct in low-cost microprocessors. Aiming to solve this issue, a simple discrete-time current control based on current measurement error is proposed, where the current performance of command tracking and disturbance rejection capabilities are enhanced. To verify the effectiveness, corresponding experimental results are carried out in a 750 W PMSM drive test rig.

Authors

Institutions

Publication Details

Published
2025-05-18
DOI
https://doi.org/10.1109/iemdc60492.2025.11060994
Primary Topic
Advanced Sensor and Control Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Discrete-time PMSM Current Control Based on Current Measurement Error

Jingwei Zhu, Shuangchun Xie, Xueping Li, Junkai Wen
Advanced Sensor and Control Systems
article

Discrete-time PMSM Current Control Based on Current Measurement Error

Jingwei Zhu, Shuangchun Xie, Xueping Li, Junkai Wen
article en

Abstract

Since permanent magnet synchronous machine (PMSM) control based on zero-order hold (ZOH) discretization can achieve better performance under low carrier ratio, it has attracted widespread attention from both academia and industry. However, due to its complex structure and the involvement of exponential calculations, the discrete-time current control difficultly conduct in low-cost microprocessors. Aiming to solve this issue, a simple discrete-time current control based on current measurement error is proposed, where the current performance of command tracking and disturbance rejection capabilities are enhanced. To verify the effectiveness, corresponding experimental results are carried out in a 750 W PMSM drive test rig.

Beijing Institute of Technology (CN), Hong Kong Polytechnic University (HK), Nanyang Technological University (SG), University of Aberdeen (GB)
Openalex Percentile: Top 82%
Advanced Sensor and Control Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Discrete-time PMSM Current Control Based on Current Measurement Error — Jingwei Zhu, Shuangchun Xie, et al. · (2025) | TGRS Research Map | TGRS