Analysis of a Charge-Sensitive Preamplifier Circuit with an Improved Time Resolution

A scheme of a charge-sensitive preamplifier (CSP) for measuring the energy and time of flight of detected particles is described. The CSP has two outputs. At the E-output, the signal is determined by the integral of the charge formed by a particle in a semiconductor detector. The signal amplitude at this output is proportional to the particle energy. At the T-output, the signal follows the shape of the detector current pulse and has a short rise time, which reduces the timing error. A circuit diagram of the CSP is shown, and calculations of the signal parameters at the E and T outputs are given. The results of modeling and the measured parameters of the proposed scheme are presented. The criterion of the expediency of using the time channel of the CSP depending on the radiation time of the radiator crystal or the charge collection time is obtained. The CSP is intended for use in photon spectrometers based on PWO crystals and avalanche photodiodes, but it can also be used in spectrometers with other types of semiconductor detectors.

Authors

Institutions

Publication Details

Journal
Instruments and Experimental Techniques
Published
2025-04-01
DOI
https://doi.org/10.1134/s0020441225700435
Primary Topic
Analog and Mixed-Signal Circuit Design
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of a Charge-Sensitive Preamplifier Circuit with an Improved Time Resolution

Yu. G. Sibiryak
Instruments and Experimental Techniques
Analog and Mixed-Signal Circuit Design
article

Analysis of a Charge-Sensitive Preamplifier Circuit with an Improved Time Resolution

Yu. G. Sibiryak
article en

Abstract

A scheme of a charge-sensitive preamplifier (CSP) for measuring the energy and time of flight of detected particles is described. The CSP has two outputs. At the E-output, the signal is determined by the integral of the charge formed by a particle in a semiconductor detector. The signal amplitude at this output is proportional to the particle energy. At the T-output, the signal follows the shape of the detector current pulse and has a short rise time, which reduces the timing error. A circuit diagram of the CSP is shown, and calculations of the signal parameters at the E and T outputs are given. The results of modeling and the measured parameters of the proposed scheme are presented. The criterion of the expediency of using the time channel of the CSP depending on the radiation time of the radiator crystal or the charge collection time is obtained. The CSP is intended for use in photon spectrometers based on PWO crystals and avalanche photodiodes, but it can also be used in spectrometers with other types of semiconductor detectors.

Instruments and Experimental TechniquesVol. 68(2)
Kurchatov Institute (RU)
Affordable and clean energy
Openalex Percentile: Top 85%
Analog and Mixed-Signal Circuit Design
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.