Evaluating Stress Distribution in Bone Adjacent to Implant in Various Abutment-Implant Connection Designs

BACKGROUNDThe biomechanical integrity of dental implants is significantly influenced by the design of the abutment-implant connection. Different connection geometries can alter stress transfer to the surrounding bone, which may impact implant longevity and osseointegration. This study aims to assess and compare the stress distribution in peri-implant bone associated with three commonly used abutment-implant connection designs: external hex, internal hex, and conical connection. MATERIALS AND METHODSA three-dimensional finite element analysis (FEA) was performed using computer-aided design (CAD) models of mandibular bone with a single implant in the posterior region. Implants with external hex, internal hex, and conical abutment connections were analyzed. A vertical load of 150 N and oblique load of 100 N at 30° were applied to simulate masticatory forces. Stress distribution in cortical and cancellous bone was evaluated using von Mises criteria. RESULTSUnder vertical loading, the maximum stress observed in cortical bone was 55.2 MPa for the external hex, 48.6 MPa for the internal hex, and 36.9 MPa for the conical connection. Oblique loading yielded higher stress values: 78.4 MPa for the external hex, 66.7 MPa for the internal hex, and 52.3 MPa for the conical connection. Cancellous bone exhibited lower overall stress values in all models. The conical connection demonstrated the most favorable stress distribution, with reduced stress concentration at the crestal bone. CONCLUSIONThe type of abutment-implant connection significantly influences stress distribution in adjacent bone. Conical connections exhibit superior biomechanical performance by minimizing stress concentration, suggesting their potential benefit in enhancing long-term implant stability.

Authors

Publication Details

Journal
International Journal of Environmental Sciences
Published
2025-05-23
DOI
https://doi.org/10.64252/2sg8nt44
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluating Stress Distribution in Bone Adjacent to Implant in Various Abutment-Implant Connection Designs

Anil K. Pradhan, A.K. Panda, Shree Mishra, S P Sahu et al.
International Journal of Environmental Sciences
Dental Implant Techniques and Outcomes
article

Evaluating Stress Distribution in Bone Adjacent to Implant in Various Abutment-Implant Connection Designs

Anil K. Pradhan, A.K. Panda, Shree Mishra, S P Sahu, Sushil Kumar Sahoo, Tonmoy Ranu
article en

Abstract

BACKGROUNDThe biomechanical integrity of dental implants is significantly influenced by the design of the abutment-implant connection. Different connection geometries can alter stress transfer to the surrounding bone, which may impact implant longevity and osseointegration. This study aims to assess and compare the stress distribution in peri-implant bone associated with three commonly used abutment-implant connection designs: external hex, internal hex, and conical connection. MATERIALS AND METHODSA three-dimensional finite element analysis (FEA) was performed using computer-aided design (CAD) models of mandibular bone with a single implant in the posterior region. Implants with external hex, internal hex, and conical abutment connections were analyzed. A vertical load of 150 N and oblique load of 100 N at 30° were applied to simulate masticatory forces. Stress distribution in cortical and cancellous bone was evaluated using von Mises criteria. RESULTSUnder vertical loading, the maximum stress observed in cortical bone was 55.2 MPa for the external hex, 48.6 MPa for the internal hex, and 36.9 MPa for the conical connection. Oblique loading yielded higher stress values: 78.4 MPa for the external hex, 66.7 MPa for the internal hex, and 52.3 MPa for the conical connection. Cancellous bone exhibited lower overall stress values in all models. The conical connection demonstrated the most favorable stress distribution, with reduced stress concentration at the crestal bone. CONCLUSIONThe type of abutment-implant connection significantly influences stress distribution in adjacent bone. Conical connections exhibit superior biomechanical performance by minimizing stress concentration, suggesting their potential benefit in enhancing long-term implant stability.

International Journal of Environmental SciencesVol. 11(6s)
Openalex Percentile: Top 77%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Evaluating Stress Distribution in Bone Adjacent to Implant in Various Abutment-Implant Connection Designs — Anil K. Pradhan, A.K. Panda, et al. · International Journal of Environmental Sciences (2025) | TGRS Research Map | TGRS