Effect of Rotor Type on Open-Set Derating Operations of Multi-Three-Phase Synchronous Machines

Multi-three-phase machines have attracted considerable interest in several fields thanks to the enhanced fault tolerance and the reduced phase current, adopting standard three-phase inverters instead of special custom converters. However, the fault-tolerance and the quality of the derated performance is strongly dependent to the winding topology and the type of rotor adopted. This study compares two 12-phases machines with distinctive rotor structure and magnetic behaviors: one with high anisotropy and low PM content and the other with lower anisotropy and dominant PM flux linkage. Efficiency and torque ripple are included in the comparison, both in healthy and open-set derated conditions. The results shows that derating is not crucial on an average point of view, but can significantly increase the torque ripple and, in some scenarios, to further reduced operating area. Notably, the high-anisotropy machine demonstrates superior field-weakening performance, whereas the motor with greater PM flux linkage achieves better derated output below base speed. These findings highlight the importance of rotor selection in optimizing multi-three-phase drives, according to the specific application.

Authors

Institutions

Publication Details

Published
2025-05-18
DOI
https://doi.org/10.1109/iemdc60492.2025.11060950
Citations
1
Primary Topic
Electric Motor Design and Analysis
Type
article
Field-Weighted Citation Impact
0.73
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of Rotor Type on Open-Set Derating Operations of Multi-Three-Phase Synchronous Machines

Simone Ferrari, Sandro Rubino, Gianmario Pellegrino
1 citations
Electric Motor Design and Analysis
0.73
article

Effect of Rotor Type on Open-Set Derating Operations of Multi-Three-Phase Synchronous Machines

Simone Ferrari, Sandro Rubino, Gianmario Pellegrino
article en
1 citations

Abstract

Multi-three-phase machines have attracted considerable interest in several fields thanks to the enhanced fault tolerance and the reduced phase current, adopting standard three-phase inverters instead of special custom converters. However, the fault-tolerance and the quality of the derated performance is strongly dependent to the winding topology and the type of rotor adopted. This study compares two 12-phases machines with distinctive rotor structure and magnetic behaviors: one with high anisotropy and low PM content and the other with lower anisotropy and dominant PM flux linkage. Efficiency and torque ripple are included in the comparison, both in healthy and open-set derated conditions. The results shows that derating is not crucial on an average point of view, but can significantly increase the torque ripple and, in some scenarios, to further reduced operating area. Notably, the high-anisotropy machine demonstrates superior field-weakening performance, whereas the motor with greater PM flux linkage achieves better derated output below base speed. These findings highlight the importance of rotor selection in optimizing multi-three-phase drives, according to the specific application.

Politecnico di Torino (IT), Ferrari (Italy) (IT)
Affordable and clean energy
Openalex Percentile: Top 26%
Electric Motor Design and Analysis
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.