Numerical simulations for neutron detector optimization

Abstract In this work, simulations are conducted to optimize a Silicon Carbide (SiC) detector for the detection of 14.1 MeV neutrons [1]. The device features an active thickness achieved through epitaxial growth of 250 μm and an active area of 25 mm 2 . In the first stage of the FLUKA simulations, the performance of the SiC detector is compared with Diamond and Silicon detectors of identical geometry. Furthermore, FLUKA simulations show saturation in alpha-particle production at a SiC thickness of approximately 200 μm. Finally, numerical simulations using Synopsys tools are employed to optimize the edge structure of the SiC detector.

Authors

Institutions

Publication Details

Journal
Journal of Instrumentation
Published
2025-07-01
DOI
https://doi.org/10.1088/1748-0221/20/07/c07013
Primary Topic
Particle Detector Development and Performance
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Numerical simulations for neutron detector optimization

Francesco La Via, S. De Luca, Enrico Sangregorio, T. Minniti et al.
1 links
Journal of Instrumentation
Particle Detector Development and Performance
article

Numerical simulations for neutron detector optimization

Francesco La Via, S. De Luca, Enrico Sangregorio, T. Minniti, A. Muoio, Alfio Samuele Mancuso
article en

Abstract

Abstract In this work, simulations are conducted to optimize a Silicon Carbide (SiC) detector for the detection of 14.1 MeV neutrons [1]. The device features an active thickness achieved through epitaxial growth of 250 μm and an active area of 25 mm 2 . In the first stage of the FLUKA simulations, the performance of the SiC detector is compared with Diamond and Silicon detectors of identical geometry. Furthermore, FLUKA simulations show saturation in alpha-particle production at a SiC thickness of approximately 200 μm. Finally, numerical simulations using Synopsys tools are employed to optimize the edge structure of the SiC detector.

Journal of InstrumentationVol. 20(07)
University of Rome Tor Vergata (IT), University of Catania (IT), Institute for Microelectronics and Microsystems (IT)
Openalex Percentile: Top 93%
Particle Detector Development and Performance
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.