The Effect of Focus Film Distance Variation on Patient Absorbed Dose in Thorax Examination with Roentgen Machine in Radiology Installation of Sanjiwani Hospital Gianyar

A study has been conducted on the effect of Focus Film Distance (FFD) variation on patient absorbed dose during thorax examination at the Radiology Installation of Sanjiwani Hospital, Gianyar. This study aims to determine the effect of FFD variation and the suitability of the radiation dose received by patients whether it is still within the limits of BAPETEN's decision. The X-ray machine used was Siemens Luminos Fusion Roentgen with the FFD variation method given a distance of 110 cm, 130 cm, and 150 cm in 30 patients. Dose measurements were carried out based on radiation exposure and analyzed according to BAPETEN standards. The results showed that the greater the FFD value, the smaller the absorbed dose received by patients. The highest absorbed dose obtained for FFD 110 cm was 0.3867 mGy, 130 cm was 0.2769 mGy, and 150 cm was 0.2079 mGy below the maximum limit of 0.4 mGy set by BAPETEN, so it is safe for patients. Statistical analysis of one-way t-test showed significant results, with thitung < ttabel. This indicates that FFD variation affects the absorbed dose, and all doses remain within safe limits. Thus, thorax examination at RSUD Sanjiwani Gianyar has met the established safety standards.

Authors

Institutions

Publication Details

Journal
Kappa Journal
Published
2024-12-26
DOI
https://doi.org/10.29408/kpj.v8i3.28113
Citations
1
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.18
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Effect of Focus Film Distance Variation on Patient Absorbed Dose in Thorax Examination with Roentgen Machine in Radiology Installation of Sanjiwani Hospital Gianyar

Hery Suyanto, Ida Bagus Alit Paramarta, I Ketut Putra, Gusti Ngurah Sutapa et al.
1 citations
Kappa Journal
Advanced X-ray and CT Imaging
0.18
article

The Effect of Focus Film Distance Variation on Patient Absorbed Dose in Thorax Examination with Roentgen Machine in Radiology Installation of Sanjiwani Hospital Gianyar

Hery Suyanto, Ida Bagus Alit Paramarta, I Ketut Putra, Gusti Ngurah Sutapa, Ida Bagus Made Suryatika, I Nyoman Yosua
article en
1 citations

Abstract

A study has been conducted on the effect of Focus Film Distance (FFD) variation on patient absorbed dose during thorax examination at the Radiology Installation of Sanjiwani Hospital, Gianyar. This study aims to determine the effect of FFD variation and the suitability of the radiation dose received by patients whether it is still within the limits of BAPETEN's decision. The X-ray machine used was Siemens Luminos Fusion Roentgen with the FFD variation method given a distance of 110 cm, 130 cm, and 150 cm in 30 patients. Dose measurements were carried out based on radiation exposure and analyzed according to BAPETEN standards. The results showed that the greater the FFD value, the smaller the absorbed dose received by patients. The highest absorbed dose obtained for FFD 110 cm was 0.3867 mGy, 130 cm was 0.2769 mGy, and 150 cm was 0.2079 mGy below the maximum limit of 0.4 mGy set by BAPETEN, so it is safe for patients. Statistical analysis of one-way t-test showed significant results, with thitung < ttabel. This indicates that FFD variation affects the absorbed dose, and all doses remain within safe limits. Thus, thorax examination at RSUD Sanjiwani Gianyar has met the established safety standards.

Kappa JournalVol. 8(3)
Udayana University (ID)
Openalex Percentile: Top 48%
Advanced X-ray and CT Imaging
0.18
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

The Effect of Focus Film Distance Variation on Patient Absorbed Dose in Thorax Examination with Roentgen Machine in Radiology Installation of Sanjiwani Hospital Gianyar — Hery Suyanto, Ida Bagus Alit Paramarta, et al. · Kappa Journal (2024) | TGRS Research Map | TGRS