Menentukan Potensi Resiko Kanker pada Pemeriksaan CT Scan Toraks dengan Metode SSED

This study aims to determine the potential risk of thoracic organ cancer in CT Scan examinations using the Size-Specific Effective Dose (SSED) method, considering the importance of accurate radiation dose measurement to minimize the risk of cancer due to radiation exposure. The analysis was conducted on 30 female patients and 30 male patients in the adult category (17 - 45 years) at the Radiology Installation of Prof. Dr. I G. N. G. Ngoerah Hospital, Denpasar, using a descriptive quantitative approach with secondary data. The results showed that the Size-Specific Dose Estimate (SSDE) and SSED values ​​in female patients were 6.51 ± 0.70 mGy and 2.95 ± 0.48 mSv, respectively, while in male patients they were 6.38 ± 0.49 mGy and 2.27 ± 0.26 mSv. The risk of cancer in female patients is estimated at 0.016% and in male patients it is 0.012%. The Anova test showed a significant difference between the dose values ​​of the SSDE and SSED methods, which was caused by SSED only considering the dose of organs covered in the CT Scan image. However, the t-test showed that the doses from both methods did not exceed the BAPETEN standard No. 8 of 2011, so that the thoracic CT Scan examination in this Installation is safe and feasible to use.

Authors

Institutions

Publication Details

Journal
Kappa Journal
Published
2024-12-10
DOI
https://doi.org/10.29408/kpj.v8i3.27804
Primary Topic
Radiomics and Machine Learning in Medical Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Menentukan Potensi Resiko Kanker pada Pemeriksaan CT Scan Toraks dengan Metode SSED

I Made Yuliara, I Wayan Sudarsana, I Wayan Supardi, Gusti Ngurah Sutapa et al.
Kappa Journal
Radiomics and Machine Learning in Medical Imaging
article

Menentukan Potensi Resiko Kanker pada Pemeriksaan CT Scan Toraks dengan Metode SSED

I Made Yuliara, I Wayan Sudarsana, I Wayan Supardi, Gusti Ngurah Sutapa, Ni Nyoman Ratini, Ni Putu Aprillia Artanti Phalosa
article en

Abstract

This study aims to determine the potential risk of thoracic organ cancer in CT Scan examinations using the Size-Specific Effective Dose (SSED) method, considering the importance of accurate radiation dose measurement to minimize the risk of cancer due to radiation exposure. The analysis was conducted on 30 female patients and 30 male patients in the adult category (17 - 45 years) at the Radiology Installation of Prof. Dr. I G. N. G. Ngoerah Hospital, Denpasar, using a descriptive quantitative approach with secondary data. The results showed that the Size-Specific Dose Estimate (SSDE) and SSED values ​​in female patients were 6.51 ± 0.70 mGy and 2.95 ± 0.48 mSv, respectively, while in male patients they were 6.38 ± 0.49 mGy and 2.27 ± 0.26 mSv. The risk of cancer in female patients is estimated at 0.016% and in male patients it is 0.012%. The Anova test showed a significant difference between the dose values ​​of the SSDE and SSED methods, which was caused by SSED only considering the dose of organs covered in the CT Scan image. However, the t-test showed that the doses from both methods did not exceed the BAPETEN standard No. 8 of 2011, so that the thoracic CT Scan examination in this Installation is safe and feasible to use.

Kappa JournalVol. 8(3)
Udayana University (ID), Rumah Sakit Umum Pusat Dr. Sardjito (ID)
Openalex Percentile: Top 55%
Radiomics and Machine Learning in Medical Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.