Detection of elliptical polarization parameters using a metalens

A metalens capable of detecting the polarization ellipticity of an incident beam is considered in this paper. This metalens consists of blocks with diffraction gratings of a 140-nm height and a 220-nm period. The metalens operates as a polarizer, which depends on one transverse coordinate, and a focuser. It is capable of both separating linearly polarized radiation into two focal spots with the opposite-handed circular polarizations and detecting the circular polarization handedness and degree of its ellipticity. Operating in a wide range of wavelengths from 0.55 to 0.837 µm, the metalens can be used in the range from 0.64 to 0.837 µm to identify the incident radiation wavelength due to an almost linear shift of the focal spot in the transverse plane with the wavelength.

Authors

Publication Details

Journal
Computer Optics
Published
2025-04-01
DOI
https://doi.org/10.18287/2412-6179-co-1515
Primary Topic
Non-Destructive Testing Techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Detection of elliptical polarization parameters using a metalens

С. Д. Полетаев, A. A. Kovalev, Victor V. Kotlyar, Anton G. Nalimov et al.
Computer Optics
Non-Destructive Testing Techniques
article

Detection of elliptical polarization parameters using a metalens

С. Д. Полетаев, A. A. Kovalev, Victor V. Kotlyar, Anton G. Nalimov, Y.V. Khanenko
article en

Abstract

A metalens capable of detecting the polarization ellipticity of an incident beam is considered in this paper. This metalens consists of blocks with diffraction gratings of a 140-nm height and a 220-nm period. The metalens operates as a polarizer, which depends on one transverse coordinate, and a focuser. It is capable of both separating linearly polarized radiation into two focal spots with the opposite-handed circular polarizations and detecting the circular polarization handedness and degree of its ellipticity. Operating in a wide range of wavelengths from 0.55 to 0.837 µm, the metalens can be used in the range from 0.64 to 0.837 µm to identify the incident radiation wavelength due to an almost linear shift of the focal spot in the transverse plane with the wavelength.

Computer OpticsVol. 49(2)
Russian Science Foundation
Openalex Percentile: Top 84%
Non-Destructive Testing Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.