Biological Responses and Hemocompatibility of Diamond‐Like Carbon Thin Films on Different <scp>PEO</scp> Interlayers for Potential Cardiovascular Stent Applications

Plasma electrolytic oxidation (PEO) considerably affects controlling the degradation rate of magnesium-based implants to approach the healing period. However, the biological properties still require further improvement, particularly for blood-contact applications, such as cardiovascular stents. This research aims to study in vitro biological properties of the duplex diamond-like carbon (DLC)/plasma electrolytic oxidation (PEO) coatings as a function of various PEO middle layers for potential cardiovascular stent applications. To this aim, two different PEO coatings including silicate and phosphate compounds were applied on AZ31 substrate as middle-layers, and a top DLC layer with 1 μm thickness was successfully synthesized on them. Moreover, the role of different PEO interlayers on the degradation behavior, biocompatibility, hemocompatibility, and its mechanism are studied. Results showed a considerable decrease in degradation rate after applying the PEO process and the PEO-Ph revealed the optimized degradation performance in just PEO-coated samples. On the other side, the best degradation performance between duplex-coated samples was obtained for DLC/PEO-Si according to its higher diamond-like structure. Moreover, the viability of human umbilical vein endothelial cells on DLC/PEO-Ph was higher than that of the DLC/PEO-Si, which might be attributed to higher protein adsorption on its surface. In the case of hemocompatibility, a considerable decrease in hemolysis ratio along with remarkable improvement in clotting behavior was observed by applying the PEO process. However, the hemolysis ratio was reduced as being safe for blood-contact applications just for duplex-coated samples. In conclusion, a promising coating for blood-contact applications based on DLC/PEO in particular in the case of DLC/PEO-Si has been provided in this study.

Authors

Institutions

Publication Details

Journal
Journal of Biomedical Materials Research Part A
Published
2025-07-01
DOI
https://doi.org/10.1002/jbm.a.37953
Citations
2
Primary Topic
Magnesium Alloys: Properties and Applications
Type
article
Field-Weighted Citation Impact
1.19
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Biological Responses and Hemocompatibility of Diamond‐Like Carbon Thin Films on Different PEO Interlayers for Potential Cardiovascular Stent Applications

Nasir Shahin, M. Shamanian, Mahshid Kharaziha
2 citations
Journal of Biomedical Materials Research Part A
Magnesium Alloys: Properties and Applications
1.19
article

Biological Responses and Hemocompatibility of Diamond‐Like Carbon Thin Films on Different PEO Interlayers for Potential Cardiovascular Stent Applications

Nasir Shahin, M. Shamanian, Mahshid Kharaziha
article en
2 citations

Abstract

Plasma electrolytic oxidation (PEO) considerably affects controlling the degradation rate of magnesium-based implants to approach the healing period. However, the biological properties still require further improvement, particularly for blood-contact applications, such as cardiovascular stents. This research aims to study in vitro biological properties of the duplex diamond-like carbon (DLC)/plasma electrolytic oxidation (PEO) coatings as a function of various PEO middle layers for potential cardiovascular stent applications. To this aim, two different PEO coatings including silicate and phosphate compounds were applied on AZ31 substrate as middle-layers, and a top DLC layer with 1 μm thickness was successfully synthesized on them. Moreover, the role of different PEO interlayers on the degradation behavior, biocompatibility, hemocompatibility, and its mechanism are studied. Results showed a considerable decrease in degradation rate after applying the PEO process and the PEO-Ph revealed the optimized degradation performance in just PEO-coated samples. On the other side, the best degradation performance between duplex-coated samples was obtained for DLC/PEO-Si according to its higher diamond-like structure. Moreover, the viability of human umbilical vein endothelial cells on DLC/PEO-Ph was higher than that of the DLC/PEO-Si, which might be attributed to higher protein adsorption on its surface. In the case of hemocompatibility, a considerable decrease in hemolysis ratio along with remarkable improvement in clotting behavior was observed by applying the PEO process. However, the hemolysis ratio was reduced as being safe for blood-contact applications just for duplex-coated samples. In conclusion, a promising coating for blood-contact applications based on DLC/PEO in particular in the case of DLC/PEO-Si has been provided in this study.

Journal of Biomedical Materials Research Part AVol. 113(7)
Isfahan University of Technology (IR)
Clean water and sanitation
Openalex Percentile: Top 21%
Magnesium Alloys: Properties and Applications
1.19
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.