Method for obtaining and dual-energy processing of X-ray sinograms for identifying low-contrast ubstances in CT using sources with a continuous radiation spectrum

The article proposes and implements a method of dual-energy CT. The method allows the contrast-enhanced differentiation of one substance from another when substances have similar chemical compositions and densities. In this case, the use of standard dual-energy CT methods does not allow the unambiguous identification of the desired substance. This is because X-ray sources emit non-monochromatic radiation, and changes in object thickness lead to significant absorption of low-energy radiation. The article justifies the use of a design solution to reduce the influence of variable object thickness on the absorption of low-energy X-ray radiation. This allows dual-energy transformation to be performed not for CT slices but for sinograms obtained at different energy spectra of X-ray radiation. After reconstructing the dual-energy sinogram on a CT slice, the desired substance is unambiguously identified. The successful implementation of this method is demonstrated in the example of beryl particles embedded in muscovite. In CT slices obtained after reconstructing dual-energy sinograms, beryl particles with sizes as small as 1 mm are clearly distinguished with a total sample thickness of 30 mm.

Authors

Publication Details

Journal
Computer Optics
Published
2025-04-01
DOI
https://doi.org/10.18287/2412-6179-co-1485
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Method for obtaining and dual-energy processing of X-ray sinograms for identifying low-contrast ubstances in CT using sources with a continuous radiation spectrum

A. A. Komarskiy, S. R. Korzhenevskiy, V.V. Krinitsin
Computer Optics
Advanced X-ray and CT Imaging
article

Method for obtaining and dual-energy processing of X-ray sinograms for identifying low-contrast ubstances in CT using sources with a continuous radiation spectrum

A. A. Komarskiy, S. R. Korzhenevskiy, V.V. Krinitsin
article en

Abstract

The article proposes and implements a method of dual-energy CT. The method allows the contrast-enhanced differentiation of one substance from another when substances have similar chemical compositions and densities. In this case, the use of standard dual-energy CT methods does not allow the unambiguous identification of the desired substance. This is because X-ray sources emit non-monochromatic radiation, and changes in object thickness lead to significant absorption of low-energy radiation. The article justifies the use of a design solution to reduce the influence of variable object thickness on the absorption of low-energy X-ray radiation. This allows dual-energy transformation to be performed not for CT slices but for sinograms obtained at different energy spectra of X-ray radiation. After reconstructing the dual-energy sinogram on a CT slice, the desired substance is unambiguously identified. The successful implementation of this method is demonstrated in the example of beryl particles embedded in muscovite. In CT slices obtained after reconstructing dual-energy sinograms, beryl particles with sizes as small as 1 mm are clearly distinguished with a total sample thickness of 30 mm.

Computer OpticsVol. 49(2)
Russian Science Foundation
Openalex Percentile: Top 85%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.