Comprehensive studies on calibration parameters of the LHCb Upstream Tracker

Abstract The Upstream Tracker is a novel silicon microstrip detector installed during LHCb Upgrade 1. To maintain the necessary efficiency, its performance requires constant monitoring and evaluation of the calibration parameters of over half a million sensors. Here, recent results regarding the stability and uniformity of those parameters are presented in order to establish whether the UT forms a stable detecting system supporting reliable physics results. The input data comprise calibration scans taken regularly in the second half of 2024. They contain information on the baseline offset and different noise components. We performed extensive studies regarding the time evolution of those parameters and their spatial distributions. Our results confirm that the Upstream Tracker demonstrates stable overall performance in all analysed calibration parameters. However, several local deviations have been identified, and an ongoing effort is being made to minimise their influence on the detector's performance.

Authors

Institutions

Publication Details

Journal
Journal of Instrumentation
Published
2025-07-01
DOI
https://doi.org/10.1088/1748-0221/20/07/c07007
Primary Topic
Particle Detector Development and Performance
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comprehensive studies on calibration parameters of the LHCb Upstream Tracker

W. Krupa, Karol Mateusz Sowa
Journal of Instrumentation
Particle Detector Development and Performance
article

Comprehensive studies on calibration parameters of the LHCb Upstream Tracker

W. Krupa, Karol Mateusz Sowa
article en

Abstract

Abstract The Upstream Tracker is a novel silicon microstrip detector installed during LHCb Upgrade 1. To maintain the necessary efficiency, its performance requires constant monitoring and evaluation of the calibration parameters of over half a million sensors. Here, recent results regarding the stability and uniformity of those parameters are presented in order to establish whether the UT forms a stable detecting system supporting reliable physics results. The input data comprise calibration scans taken regularly in the second half of 2024. They contain information on the baseline offset and different noise components. We performed extensive studies regarding the time evolution of those parameters and their spatial distributions. Our results confirm that the Upstream Tracker demonstrates stable overall performance in all analysed calibration parameters. However, several local deviations have been identified, and an ongoing effort is being made to minimise their influence on the detector's performance.

Journal of InstrumentationVol. 20(07)
AGH University of Krakow (PL), Syracuse University (US)
Ministerstwo Edukacji i Nauki
Openalex Percentile: Top 93%
Particle Detector Development and Performance
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.