Thermal Comfort Assessment of Secondary School Classes In Kuala Lumpur, Malaysia

Global warming causes rapid temperature and precipitation variations, with El Niño being a prolonged cycle of this phenomenon. In Malaysia, over 250 schools closed due to extreme heat waves caused by El Niño. This study monitored the thermal comfort of classrooms at National High School Bukit Jalil and National High School Taman Yarl in Kuala Lumpur, selected for their typical design, orientation, and floor levels. The study aimed to evaluate indoor environmental conditions in these classrooms based on ASHRAE Standard 55 and ISO EN 7730, assess students’ thermal comfort perceptions, and identify influencing factors.Objective assessments were conducted for six days in March 2016, from 7:30 AM to 1:30 PM, during lesson hours. Thermal comfort variables were measured using an HD32.2 Delta Ohm Data Logger to generate the Predicted Mean Vote (PMV) model and calculate the Predicted Percentage Dissatisfied (PPD) value. Analysis revealed that none of the classrooms met ASHRAE Standard 55 comfort conditions, with all classified as warm to hot on a 7-point ASHRAE scale. A questionnaire survey assessed students’ perceptions, showing that 80%-100% were dissatisfied. Key influencing factors included seating positions, clothing insulation, classroom floor levels, and orientation.

Authors

Institutions

Publication Details

Journal
International Journal of Environmental Sciences
Published
2025-06-02
DOI
https://doi.org/10.64252/9pdcn475
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Thermal Comfort Assessment of Secondary School Classes In Kuala Lumpur, Malaysia

PA Theebaa, S. Paneerchelvam
International Journal of Environmental Sciences
Building Energy and Comfort Optimization
article

Thermal Comfort Assessment of Secondary School Classes In Kuala Lumpur, Malaysia

PA Theebaa, S. Paneerchelvam
article en

Abstract

Global warming causes rapid temperature and precipitation variations, with El Niño being a prolonged cycle of this phenomenon. In Malaysia, over 250 schools closed due to extreme heat waves caused by El Niño. This study monitored the thermal comfort of classrooms at National High School Bukit Jalil and National High School Taman Yarl in Kuala Lumpur, selected for their typical design, orientation, and floor levels. The study aimed to evaluate indoor environmental conditions in these classrooms based on ASHRAE Standard 55 and ISO EN 7730, assess students’ thermal comfort perceptions, and identify influencing factors.Objective assessments were conducted for six days in March 2016, from 7:30 AM to 1:30 PM, during lesson hours. Thermal comfort variables were measured using an HD32.2 Delta Ohm Data Logger to generate the Predicted Mean Vote (PMV) model and calculate the Predicted Percentage Dissatisfied (PPD) value. Analysis revealed that none of the classrooms met ASHRAE Standard 55 comfort conditions, with all classified as warm to hot on a 7-point ASHRAE scale. A questionnaire survey assessed students’ perceptions, showing that 80%-100% were dissatisfied. Key influencing factors included seating positions, clothing insulation, classroom floor levels, and orientation.

International Journal of Environmental SciencesVol. 11(7s)
Academy of Sciences Malaysia (MY)
Universiti Putra Malaysia
Openalex Percentile: Top 83%
Building Energy and Comfort Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.