Test–Retest Reliability of a Commercially Available Bioelectrical Impedance-Based Body Composition Analyzer in India

A bstract Introduction: Body composition assessment plays a critical role in managing various clinical conditions, including obesity, cancer, renal failure, and endocrine disorders. While dual-energy X-ray absorptiometry (DEXA) is considered the gold standard, it is often impractical for routine clinical or field use. Bioelectrical impedance analysis (BIA) has emerged as a simpler alternative and is currently recommended in sarcopenia diagnostic guidelines. Although many low-cost BIA devices are commercially available, information regarding their reliability is limited, which restricts their clinical utility. Aim: This study aimed to assess the test–retest reliability of a commercially available BIA device (Omron HBF-702T) under non-standardized conditions that reflect routine clinical settings. Forty healthy adults (mean age: 28 ± 7.5 years; 78% women; body mass index: 26.1 ± 4.4) participated after obtaining appropriate approvals and informed consent. Measurements of skeletal muscle percentage, total body fat percentage, and resting metabolic rate (RMR) were taken on two occasions, 1–4 days apart, without standardizing the timing of assessment or controlling food and fluid intake. Results: No clinically or statistically significant differences were found between the two sessions (mean differences: skeletal muscle percentage: 0.06%; body fat percentage: 0.12%; RMR: 8.5 kcal/day). All parameters demonstrated excellent test–retest reliability, with intraclass correlation coefficients and Cronbach α values as follows: skeletal muscle percentage (0.97 and 0.98), body fat percentage (0.93 and 0.96), and RMR (0.94 and 0.97). Conclusion: In conclusion, the Omron HBF-702T exhibited excellent test–retest reliability for key body composition parameters even in non-standardized settings, supporting its potential use in routine clinical practice.

Authors

Institutions

Publication Details

Journal
Journal of Society of Indian Physiotherapists
Published
2025-07-01
DOI
https://doi.org/10.4103/jsip.jsip_154_24
Primary Topic
Body Composition Measurement Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Test–Retest Reliability of a Commercially Available Bioelectrical Impedance-Based Body Composition Analyzer in India

Divya Priya Bhupal, Sundar Kumar Veluswamy, Lalitha Krishnappa, Sujeeth Chandru
1 links
Journal of Society of Indian Physiotherapists
Body Composition Measurement Techniques
article

Test–Retest Reliability of a Commercially Available Bioelectrical Impedance-Based Body Composition Analyzer in India

Divya Priya Bhupal, Sundar Kumar Veluswamy, Lalitha Krishnappa, Sujeeth Chandru
article en

Abstract

A bstract Introduction: Body composition assessment plays a critical role in managing various clinical conditions, including obesity, cancer, renal failure, and endocrine disorders. While dual-energy X-ray absorptiometry (DEXA) is considered the gold standard, it is often impractical for routine clinical or field use. Bioelectrical impedance analysis (BIA) has emerged as a simpler alternative and is currently recommended in sarcopenia diagnostic guidelines. Although many low-cost BIA devices are commercially available, information regarding their reliability is limited, which restricts their clinical utility. Aim: This study aimed to assess the test–retest reliability of a commercially available BIA device (Omron HBF-702T) under non-standardized conditions that reflect routine clinical settings. Forty healthy adults (mean age: 28 ± 7.5 years; 78% women; body mass index: 26.1 ± 4.4) participated after obtaining appropriate approvals and informed consent. Measurements of skeletal muscle percentage, total body fat percentage, and resting metabolic rate (RMR) were taken on two occasions, 1–4 days apart, without standardizing the timing of assessment or controlling food and fluid intake. Results: No clinically or statistically significant differences were found between the two sessions (mean differences: skeletal muscle percentage: 0.06%; body fat percentage: 0.12%; RMR: 8.5 kcal/day). All parameters demonstrated excellent test–retest reliability, with intraclass correlation coefficients and Cronbach α values as follows: skeletal muscle percentage (0.97 and 0.98), body fat percentage (0.93 and 0.96), and RMR (0.94 and 0.97). Conclusion: In conclusion, the Omron HBF-702T exhibited excellent test–retest reliability for key body composition parameters even in non-standardized settings, supporting its potential use in routine clinical practice.

Journal of Society of Indian PhysiotherapistsVol. 9(2)
M S Ramaiah University of Applied Sciences (IN), M.S. Ramaiah Medical College (IN)
Openalex Percentile: Top 79%
Body Composition Measurement Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.