Performance Assessment of a Newly Designed Cardiovascular Stent Using WE43 and Zn-0.8Li-0.4Mg Biocompatible Alloys

Cardiovascular stents play a vital role in treating narrowed arteries, where structural efficiency and biocompatibility are critical for long-term success. Material selection and design geometry significantly influence the mechanical performance of stents. Existing stent designs often suffer from limitations such as high foreshortening, dogboning, and recoiling, which can compromise deployment accuracy and arterial conformity. To address these limitations, this study explores both geometric optimization and novel biocompatible materials to enhance mechanical behaviour during stent expansion. The primary aim is to evaluate and compare a newly proposed stent design with an existing model using WE43 material, and further assess performance improvements using a Zn-0.8Li-0.4Mg alloy. The proposed WE43 stent design shows a remarkable reduction in foreshortening, dropping from 5.74% in the baseline paper considered for this study to just 0.79% at 0.05 mm thickness, significantly enhancing deployment precision. Dogboning remains well-controlled, increasing only slightly from –0.038% to 1.65% at the same thickness, while still staying within acceptable clinical limits. Recoiling improves notably at higher thicknesses dropping from 17.1% to 8.03% at 0.3 mm indicating improved radial stability. Compared to Zn–0.8Li–0.4Mg, WE43 exhibits more consistent foreshortening (~0.79–1.2%) and lower dogboning, confirming its superior mechanical performance for reliable cardiovascular deployment. The study establishes the significance of geometry and material synergy in stent design. Zn-0.8Li-0.4Mg emerges as a promising candidate for next-generation cardiovascular stents with improved deployment characteristics

Authors

Publication Details

Journal
Tuijin Jishu/Journal of Propulsion Technology
Published
2025-04-08
DOI
https://doi.org/10.52783/tjjpt.v46.i02.9524
Primary Topic
Metal and Thin Film Mechanics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance Assessment of a Newly Designed Cardiovascular Stent Using WE43 and Zn-0.8Li-0.4Mg Biocompatible Alloys

Shams Tabraiz Alam
4 links
Tuijin Jishu/Journal of Propulsion Technology
Metal and Thin Film Mechanics
article

Performance Assessment of a Newly Designed Cardiovascular Stent Using WE43 and Zn-0.8Li-0.4Mg Biocompatible Alloys

Shams Tabraiz Alam
article en

Abstract

Cardiovascular stents play a vital role in treating narrowed arteries, where structural efficiency and biocompatibility are critical for long-term success. Material selection and design geometry significantly influence the mechanical performance of stents. Existing stent designs often suffer from limitations such as high foreshortening, dogboning, and recoiling, which can compromise deployment accuracy and arterial conformity. To address these limitations, this study explores both geometric optimization and novel biocompatible materials to enhance mechanical behaviour during stent expansion. The primary aim is to evaluate and compare a newly proposed stent design with an existing model using WE43 material, and further assess performance improvements using a Zn-0.8Li-0.4Mg alloy. The proposed WE43 stent design shows a remarkable reduction in foreshortening, dropping from 5.74% in the baseline paper considered for this study to just 0.79% at 0.05 mm thickness, significantly enhancing deployment precision. Dogboning remains well-controlled, increasing only slightly from –0.038% to 1.65% at the same thickness, while still staying within acceptable clinical limits. Recoiling improves notably at higher thicknesses dropping from 17.1% to 8.03% at 0.3 mm indicating improved radial stability. Compared to Zn–0.8Li–0.4Mg, WE43 exhibits more consistent foreshortening (~0.79–1.2%) and lower dogboning, confirming its superior mechanical performance for reliable cardiovascular deployment. The study establishes the significance of geometry and material synergy in stent design. Zn-0.8Li-0.4Mg emerges as a promising candidate for next-generation cardiovascular stents with improved deployment characteristics

Tuijin Jishu/Journal of Propulsion TechnologyVol. 46(02)
Openalex Percentile: Top 82%
Metal and Thin Film Mechanics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.