Influence of Field of View and Bowtie Filtration on Cone Beam Computed Tomography Image Quality and Scatter-to-Primary Ratio
Purpose/Aim: The image quality (IQ) of cone-beam computed tomography (CBCT) is often reduced due to X-ray scatter, causing issues such as shading, skin-line artifacts, decreased contrast-to-noise ratio, and inaccurate computed tomography (CT) numbers. This study establishes six metrics for assessing IQ, focusing on both traditional metrics, such as contrast-to-noise ratio, and clinically relevant measures of CT signal accuracy. Using a commercial CBCT system for image-guided radiation therapy (IGRT), the study examines how these metrics vary with axial field-of-view (FOV z ) and bowtie filter use to understand the effects of X-ray scatter on IQ. Materials and Methods: Catphan-600 phantom was scanned at five longitudinal FOV z settings (2–27 cm, Superior-Inferior) with and without a bowtie filter, and all software-based scatter corrections were disabled. Six metrics were evaluated: shading (m shading ), periphery accuracy (m periphery ), noise (m noise ), contrast-to-noise ratio (m CNR ), CT number accuracy (m CT# ), and linearity (m linearity ). Results: All six metrics demonstrated a notable decline in IQ as the FOV z increased from 2 to 27 cm. Specifically, the CNR decreased by half, while m shading increased by 250 HU. The bowtie filter improved CT number accuracy at the periphery by approximately 100–140 HU, partially mitigating the impact of a larger FOV z on IQ. Conclusions: As the FOV z increases, quantitative assessments reveal significant artifacts. Using a bowtie filter improves CNR and CT number accuracy while reducing shading and skin-line artifacts. For enhanced IQ in clinical therapy, minimizing the FOV z is recommended. The evaluation framework established in this study provides a valuable tool for system comparison and assessing scatter correction techniques, aiding in accurate low-contrast detection and supporting advancements in online and adaptive radiotherapy.
Authors
- Noor Mail (ORCID: https://orcid.org/0000-0002-9334-2709)
- Khalid M Alshamrani (ORCID: https://orcid.org/0000-0002-0950-3945)
- Behram Khan (ORCID: https://orcid.org/0000-0002-9795-9466)
Institutions
- King Saud bin Abdulaziz University for Health Sciences (SA)
- University of Toronto (CA)
- King Abdullah International Medical Research Center (SA)
- UPMC Hillman Cancer Center (US)
- University of Pittsburgh Medical Center (US)
- National Guard Health Affairs (SA)
Publication Details
- Journal
- Journal of Medical Physics
- Published
- 2025-04-01
- DOI
- https://doi.org/10.4103/jmp.jmp_191_24
- Primary Topic
- Medical Imaging Techniques and Applications
- Type
- article
- Field-Weighted Citation Impact
- 0.00