Dosimetric Comparison of Tangential Beam and Equally Spaced Beam Intensity-modulated Radiation Therapy in Right Breast Cancer Following Breast-conserving Surgery: A Retrospective Study

Objective: This study aimed to evaluate and compare the dosimetric performance and treatment efficiency of two intensity-modulated radiation therapy (IMRT) techniques – tangential field IMRT (Tan_IMRT) and equally spaced beam IMRT (Esb_IMRT) – in patients with right-sided breast cancer following breast-conserving surgery (BCS). Materials and Methods: A total of 25 female patients who underwent BCS for right-sided breast cancer and received adjuvant radiotherapy were included in this retrospective study. All patients were treated with whole-breast hypofractionated radiotherapy, delivering 40.05 Gy in 15 fractions. Each patient’s treatment plans were generated using the Eclipse Treatment Planning System, employing Tan_IMRT and Esb_IMRT techniques on a TrueBeam SVC linear accelerator equipped with a high-definition multileaf collimator. Various dosimetric parameters were evaluated, including the conformity index (CI), homogeneity index (HI), dose–volume histogram metrics for organs at risk, and monitor units (MUs). Results: In right-sided breast radiotherapy following BCS, Esb_IMRT demonstrated a superior CI and HI compared to Tan_IMRT. In addition, Esb_IMRT achieved lower ipsilateral lung doses, as reflected by reduced V20%, V5%, and mean dose (D mean ). However, Tan_IMRT resulted in a lower D mean for the contralateral breast. Conclusion: Tan_IMRT shows reduced radiation exposure to the heart, contralateral lung, and contralateral breast. Furthermore, Tan_IMRT delivers doses with fewer MUs. In contrast, Esb_IMRT gives superior CI and HI while achieving lower doses to the ipsilateral lung and liver. Hence, Tan_IMRT can be suitable for younger patients.

Authors

Institutions

Publication Details

Journal
Journal of Medical Physics
Published
2025-04-01
DOI
https://doi.org/10.4103/jmp.jmp_49_25
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dosimetric Comparison of Tangential Beam and Equally Spaced Beam Intensity-modulated Radiation Therapy in Right Breast Cancer Following Breast-conserving Surgery: A Retrospective Study

Bharath Pandu, KN Govindarajan, Gayatri Gowrishankar, Saro Jacob et al.
1 links
Journal of Medical Physics
Advanced Radiotherapy Techniques
article

Dosimetric Comparison of Tangential Beam and Equally Spaced Beam Intensity-modulated Radiation Therapy in Right Breast Cancer Following Breast-conserving Surgery: A Retrospective Study

Bharath Pandu, KN Govindarajan, Gayatri Gowrishankar, Saro Jacob, Anil Kumar, E Rajadurai
article en

Abstract

Objective: This study aimed to evaluate and compare the dosimetric performance and treatment efficiency of two intensity-modulated radiation therapy (IMRT) techniques – tangential field IMRT (Tan_IMRT) and equally spaced beam IMRT (Esb_IMRT) – in patients with right-sided breast cancer following breast-conserving surgery (BCS). Materials and Methods: A total of 25 female patients who underwent BCS for right-sided breast cancer and received adjuvant radiotherapy were included in this retrospective study. All patients were treated with whole-breast hypofractionated radiotherapy, delivering 40.05 Gy in 15 fractions. Each patient’s treatment plans were generated using the Eclipse Treatment Planning System, employing Tan_IMRT and Esb_IMRT techniques on a TrueBeam SVC linear accelerator equipped with a high-definition multileaf collimator. Various dosimetric parameters were evaluated, including the conformity index (CI), homogeneity index (HI), dose–volume histogram metrics for organs at risk, and monitor units (MUs). Results: In right-sided breast radiotherapy following BCS, Esb_IMRT demonstrated a superior CI and HI compared to Tan_IMRT. In addition, Esb_IMRT achieved lower ipsilateral lung doses, as reflected by reduced V20%, V5%, and mean dose (D mean ). However, Tan_IMRT resulted in a lower D mean for the contralateral breast. Conclusion: Tan_IMRT shows reduced radiation exposure to the heart, contralateral lung, and contralateral breast. Furthermore, Tan_IMRT delivers doses with fewer MUs. In contrast, Esb_IMRT gives superior CI and HI while achieving lower doses to the ipsilateral lung and liver. Hence, Tan_IMRT can be suitable for younger patients.

Journal of Medical PhysicsVol. 50(2)
PSG Institute of Medical Sciences & Research (IN), Bangalore Baptist Hospital (IN)
Openalex Percentile: Top 78%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.