Normalization of non-sinusoidality indicators of magnetoelectric generator under an autonomous mode of operation

The object of this study is a magnetoelectric generator with an excitation system based on permanent magnets and an additional magnetic system in the form of ferromagnetic shunts. This paper considers the task of non-sinusoidal voltage in a local electrical network with a magnetoelectric generator. This phenomenon negatively affects the operation of consumers and reduces the energy efficiency of the system. The work investigates the causes of harmonic distortion and proposes a method for reducing their impact. This helps ensure stable and high-quality operation of consumers in the electrical network. The generated voltage was studied in terms of non-sinusoidality for a magnetoelectric generator at different load levels in isolated operation. The non-compliance of the generated voltage with the requirements of the current standard in terms of the relative voltage of individual harmonics and the total harmonic distortion factor (THDU) was established. The dependences of the relative voltage of harmonics on the generator load level in the range from idle to nominal load were determined. The parameters of single-frequency resonant filters were calculated, which enable the normalization of the generated voltage according to the non-sinusoidality indicators under the conditions of isolated operation of the generator with a rated load. A feature of the results is the design of adaptive voltage non-sinusoidality filters that take into account the specificity of operation of the magnetoelectric generator in the local network. Analysis of the generator output voltage revealed that under an isolated operation mode, it is necessary to install filters of the 3rd, 5th, 9th, 21st, and 23rd harmonics in the entire generator load range. The absence of harmonic resonance phenomena is shown if filters with fixed parameters are used in the generator load range from idle to rated load

Authors

Institutions

Publication Details

Journal
Eastern-European Journal of Enterprise Technologies
Published
2025-06-27
DOI
https://doi.org/10.15587/1729-4061.2025.332187
Primary Topic
Geotechnical and Geomechanical Engineering
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Normalization of non-sinusoidality indicators of magnetoelectric generator under an autonomous mode of operation

Teimuraz Luarsabovych Katsadze, Mykhailo Kovalenko, Naina Buslova, Volodymyr Chyzhevskyi et al.
Eastern-European Journal of Enterprise Technologies
Geotechnical and Geomechanical Engineering
article

Normalization of non-sinusoidality indicators of magnetoelectric generator under an autonomous mode of operation

Teimuraz Luarsabovych Katsadze, Mykhailo Kovalenko, Naina Buslova, Volodymyr Chyzhevskyi, Vadim Chumack
article en

Abstract

The object of this study is a magnetoelectric generator with an excitation system based on permanent magnets and an additional magnetic system in the form of ferromagnetic shunts. This paper considers the task of non-sinusoidal voltage in a local electrical network with a magnetoelectric generator. This phenomenon negatively affects the operation of consumers and reduces the energy efficiency of the system. The work investigates the causes of harmonic distortion and proposes a method for reducing their impact. This helps ensure stable and high-quality operation of consumers in the electrical network. The generated voltage was studied in terms of non-sinusoidality for a magnetoelectric generator at different load levels in isolated operation. The non-compliance of the generated voltage with the requirements of the current standard in terms of the relative voltage of individual harmonics and the total harmonic distortion factor (THDU) was established. The dependences of the relative voltage of harmonics on the generator load level in the range from idle to nominal load were determined. The parameters of single-frequency resonant filters were calculated, which enable the normalization of the generated voltage according to the non-sinusoidality indicators under the conditions of isolated operation of the generator with a rated load. A feature of the results is the design of adaptive voltage non-sinusoidality filters that take into account the specificity of operation of the magnetoelectric generator in the local network. Analysis of the generator output voltage revealed that under an isolated operation mode, it is necessary to install filters of the 3rd, 5th, 9th, 21st, and 23rd harmonics in the entire generator load range. The absence of harmonic resonance phenomena is shown if filters with fixed parameters are used in the generator load range from idle to rated load

Eastern-European Journal of Enterprise TechnologiesVol. 3(8 (135))
National Technical University of Ukraine “Igor Sikorsky Kyiv Polytechnic Institute” (UA)
Openalex Percentile: Top 82%
Geotechnical and Geomechanical Engineering
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.