The necessity of accounting for secondary effects in fire resistance calculations of buildings and structures

Conventional fire resistance calculations evaluate individual structural elements (beams, columns, walls, floor slabs) based on their material properties. Current analysis methods, including standard fire resistance tests, fail to account for actual structural interactions in building systems. Building structures inherently function as interconnected systems through various connections (pinned, hinged, continuous, or multi-span configurations). Consequently, either the complete failure of a load-bearing element during fire exposure or even just the alteration of its stiffness properties can trigger significant force redistribution. This may lead to structural behavior changes ranging from localized damage to potential progressive collapse. Furthermore, the performance of structural connections during and after fire exposure critically influences the global stability of the building's load-bearing system. The standard fire resistance calculation criteria are based on two key requirements: firstly, a building's fire resistance duration must surpass the regulatory-mandated timeframe determined by its specific occupancy classification, and secondly, the overall fire resistance depends directly on the fire resistance ratings of the building's principal structural components. All buildings must comply with fundamental functional requirements specified in regulatory documents, including provisions for safe evacuation routes, control of internal fire spread pathways, prevention of external fire propagation, and ensuring fire service access to firefighting equipment. It should be emphasized that building codes establish minimum necessary standards for protect Occupant and public safety, focusing primarily on health and life protection rather than structural preservation, though damage limitation measures, while not explicitly required, are not precluded by these regulations. Building codes are not intended to mitigate financial losses from fire incidents, a crucial consideration for designing building fire protection systems when regulatory requirements alone prove insufficient to satisfy client specifications. The paramount requirement for building structures during internal fire propagation scenarios is as follows: A building must be designed and constructed to maintain structural stability for a code-specified duration during fire exposure. The requirements for maintaining a building's stability during a reasonably sufficient time traditionally correspond to the structure's survival time in standard fire resistance tests. Consequently, in addition to mechanical effects, one must consider changes in both thermal and mechanical properties of steel resulting from structural heating during a fire.

Authors

Institutions

Publication Details

Journal
Building constructions Theory and Practice
Published
2025-06-28
DOI
https://doi.org/10.32347/2522-4182.16.2025.145-157
Primary Topic
Fire effects on concrete materials
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The necessity of accounting for secondary effects in fire resistance calculations of buildings and structures

Leonid Skoruk
Building constructions Theory and Practice
Fire effects on concrete materials
article

The necessity of accounting for secondary effects in fire resistance calculations of buildings and structures

Leonid Skoruk
article en

Abstract

Conventional fire resistance calculations evaluate individual structural elements (beams, columns, walls, floor slabs) based on their material properties. Current analysis methods, including standard fire resistance tests, fail to account for actual structural interactions in building systems. Building structures inherently function as interconnected systems through various connections (pinned, hinged, continuous, or multi-span configurations). Consequently, either the complete failure of a load-bearing element during fire exposure or even just the alteration of its stiffness properties can trigger significant force redistribution. This may lead to structural behavior changes ranging from localized damage to potential progressive collapse. Furthermore, the performance of structural connections during and after fire exposure critically influences the global stability of the building's load-bearing system. The standard fire resistance calculation criteria are based on two key requirements: firstly, a building's fire resistance duration must surpass the regulatory-mandated timeframe determined by its specific occupancy classification, and secondly, the overall fire resistance depends directly on the fire resistance ratings of the building's principal structural components. All buildings must comply with fundamental functional requirements specified in regulatory documents, including provisions for safe evacuation routes, control of internal fire spread pathways, prevention of external fire propagation, and ensuring fire service access to firefighting equipment. It should be emphasized that building codes establish minimum necessary standards for protect Occupant and public safety, focusing primarily on health and life protection rather than structural preservation, though damage limitation measures, while not explicitly required, are not precluded by these regulations. Building codes are not intended to mitigate financial losses from fire incidents, a crucial consideration for designing building fire protection systems when regulatory requirements alone prove insufficient to satisfy client specifications. The paramount requirement for building structures during internal fire propagation scenarios is as follows: A building must be designed and constructed to maintain structural stability for a code-specified duration during fire exposure. The requirements for maintaining a building's stability during a reasonably sufficient time traditionally correspond to the structure's survival time in standard fire resistance tests. Consequently, in addition to mechanical effects, one must consider changes in both thermal and mechanical properties of steel resulting from structural heating during a fire.

Building constructions Theory and Practice(16)
Kyiv National University of Construction and Architecture (UA)
Openalex Percentile: Top 83%
Fire effects on concrete materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.