A Novel RP-HPLC Analytical Method Development and Validation of Berberine In Bulk and Polyherbal Formulation

A simple, precise, accurate and reproducible method for the estimation of Berberine in bulk and polyherbal formulations by RP-HPLC. The separation of the phytochemical using RP-HPLC was achieved on a SHISEIDO CAPSELL PAK C18, (250×4.6mm, 5 micron) size column with a mobile phase consisting Acetonitrile : 0.1% Orthophosphoric acid (60:40), using a flow rate of 1 mL/min and detecting a wavelength of 265 nm.The retention times was observed to be 2.678 for Berberine respectively. Linearity was found to be 2, 4, 6, 8, 10μg/ml for Berberine, with correlation of coefficient of 0.996 respectively. For system precision the %RSD for Berberine was found to be less than 2.0. the developed method was succesfully validated for Accuracy, Precision, Linearity,Limit of Detection, Limit of Quantification & Robustness. Hence, this method can be used for estimation of Berberine in bulk and polyherbal formulations by RP-HPLC.

Authors

Publication Details

Journal
International Journal of Research in Pharmacy and Allied Science
Published
2025-01-01
DOI
https://doi.org/10.71431/ijrpas.2025.4612
Primary Topic
Drug Solubulity and Delivery Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Novel RP-HPLC Analytical Method Development and Validation of Berberine In Bulk and Polyherbal Formulation

B. Rani, M. Ashritha, Kandula Venkat Navya
International Journal of Research in Pharmacy and Allied Science
Drug Solubulity and Delivery Systems
article

A Novel RP-HPLC Analytical Method Development and Validation of Berberine In Bulk and Polyherbal Formulation

B. Rani, M. Ashritha, Kandula Venkat Navya
article en

Abstract

A simple, precise, accurate and reproducible method for the estimation of Berberine in bulk and polyherbal formulations by RP-HPLC. The separation of the phytochemical using RP-HPLC was achieved on a SHISEIDO CAPSELL PAK C18, (250×4.6mm, 5 micron) size column with a mobile phase consisting Acetonitrile : 0.1% Orthophosphoric acid (60:40), using a flow rate of 1 mL/min and detecting a wavelength of 265 nm.The retention times was observed to be 2.678 for Berberine respectively. Linearity was found to be 2, 4, 6, 8, 10μg/ml for Berberine, with correlation of coefficient of 0.996 respectively. For system precision the %RSD for Berberine was found to be less than 2.0. the developed method was succesfully validated for Accuracy, Precision, Linearity,Limit of Detection, Limit of Quantification & Robustness. Hence, this method can be used for estimation of Berberine in bulk and polyherbal formulations by RP-HPLC.

International Journal of Research in Pharmacy and Allied ScienceVol. 04(06)
Openalex Percentile: Top 88%
Drug Solubulity and Delivery Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.