The impact of cross-validation choices on pBCI classification metrics: lessons for transparent reporting

Neuroadaptive technologies are a type of passive Brain-computer interface (pBCI) that aim to incorporate implicit user-state information into human-machine interactions by monitoring neurophysiological signals. Evaluating machine learning and signal processing approaches represents a core aspect of research into neuroadaptive technologies. These evaluations are often conducted under controlled laboratory settings and offline, where exhaustive analyses are possible. However, the manner in which classifiers are evaluated offline has been shown to impact reported accuracy levels, possibly biasing conclusions. In the current study, we investigated one of these sources of bias, the choice of cross-validation scheme, which is often not reported in sufficient detail. Across three independent electroencephalography (EEG) n-back datasets and 74 participants, we show how metrics and conclusions based on the same data can diverge with different cross-validation choices. A comparison of cross-validation schemes in which train and test subset boundaries either respect the block-structure of the data collection or not, illustrated how the relative performance of classifiers varies significantly with the evaluation method used. By computing bootstrapped 95% confidence intervals of differences across datasets, we showed that classification accuracies of Riemannian minimum distance (RMDM) classifiers may differ by up to 12.7% while those of a Filter Bank Common Spatial Pattern (FBCSP) based linear discriminant analysis (LDA) may differ by up to 30.4%. These differences across cross-validation implementations may impact the conclusions presented in research papers, which can complicate efforts to foster reproducibility. Our results exemplify why detailed reporting on data splitting procedures should become common practice.

Authors

Institutions

Publication Details

Journal
Frontiers in Neuroergonomics
Published
2025-07-01
DOI
https://doi.org/10.3389/fnrgo.2025.1582724
Citations
1
Primary Topic
EEG and Brain-Computer Interfaces
Type
article
Field-Weighted Citation Impact
1.43

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The impact of cross-validation choices on pBCI classification metrics: lessons for transparent reporting

Stephen Fairclough, Frédéric Dehais, Frank Schroeder, Matthew Richins
1 citations
Frontiers in Neuroergonomics
EEG and Brain-Computer Interfaces
1.43
article

The impact of cross-validation choices on pBCI classification metrics: lessons for transparent reporting

Stephen Fairclough, Frédéric Dehais, Frank Schroeder, Matthew Richins
article en
1 citations

Abstract

Neuroadaptive technologies are a type of passive Brain-computer interface (pBCI) that aim to incorporate implicit user-state information into human-machine interactions by monitoring neurophysiological signals. Evaluating machine learning and signal processing approaches represents a core aspect of research into neuroadaptive technologies. These evaluations are often conducted under controlled laboratory settings and offline, where exhaustive analyses are possible. However, the manner in which classifiers are evaluated offline has been shown to impact reported accuracy levels, possibly biasing conclusions. In the current study, we investigated one of these sources of bias, the choice of cross-validation scheme, which is often not reported in sufficient detail. Across three independent electroencephalography (EEG) n-back datasets and 74 participants, we show how metrics and conclusions based on the same data can diverge with different cross-validation choices. A comparison of cross-validation schemes in which train and test subset boundaries either respect the block-structure of the data collection or not, illustrated how the relative performance of classifiers varies significantly with the evaluation method used. By computing bootstrapped 95% confidence intervals of differences across datasets, we showed that classification accuracies of Riemannian minimum distance (RMDM) classifiers may differ by up to 12.7% while those of a Filter Bank Common Spatial Pattern (FBCSP) based linear discriminant analysis (LDA) may differ by up to 30.4%. These differences across cross-validation implementations may impact the conclusions presented in research papers, which can complicate efforts to foster reproducibility. Our results exemplify why detailed reporting on data splitting procedures should become common practice.

Frontiers in NeuroergonomicsVol. 6
Defence Science and Technology Laboratory (GB), Université Fédérale de Toulouse Midi-Pyrénées (FR), Institut Superieur de l'Aeronautique et de l'Espace (ISAE-SUPAERO) (FR), Liverpool John Moores University (GB)
Defence Science and Technology Laboratory
Reduced inequalities
Openalex Percentile: Top 18%
EEG and Brain-Computer Interfaces
1.43
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.