Utilizing layer-parameter of shear horizontal surface acoustic wave biosensor for lipoprotein particle sizing

Shear horizontal surface acoustic wave (SH-SAW) sensors are widely used in biosensing for marker detection and can also measure particle size. This study leverages SH-SAW technology with a reflective-type design and unique packaging technology to distinguish lipoprotein sizes on a 3 × 5 mm sensor chip, addressing the limitations of traditional, time-consuming methods like chromatography and nuclear magnetic resonance (NMR). A 250 MHz SH-SAW biosensor on 36° rotated Y-cut 90° X-propagating quartz substrates was used, with ApoA1, ApoB48, ApoB100, and Lp(a) antibodies immobilized on a gold surface to capture lipoproteins from human plasma. The ratio of velocity to attenuation changes, defined as the layer-parameter, was analyzed, and numerical calculations validated the experimental results. ApoA1-, ApoB48- and ApoB100-containing lipoproteins, as well as Lp(a), exhibited different sizes, with corresponding layer-parameter values of -0.398 ± 0.009, -1.133 ± 0.043, -0.661 ± 0.024, and -0.497 ± 0.035, respectively. These values demonstrated a strong correlation (<i>R</i> = 0.9987) between lipoprotein size and the increase in layer thickness. This study highlights that analyzing layer-parameters enables the estimation of lipoprotein size, thereby expanding the clinical potential of SH-SAW biosensors for point-of-care testing (POCT).

Authors

Institutions

Publication Details

Journal
Lab on a Chip
Published
2025-01-01
DOI
https://doi.org/10.1039/d5lc00444f
Primary Topic
Acoustic Wave Resonator Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Utilizing layer-parameter of shear horizontal surface acoustic wave biosensor for lipoprotein particle sizing

Chia-Hsuan Cheng, Hiromi Yatsuda, Jun Kondoh
Lab on a Chip
Acoustic Wave Resonator Technologies
article

Utilizing layer-parameter of shear horizontal surface acoustic wave biosensor for lipoprotein particle sizing

Chia-Hsuan Cheng, Hiromi Yatsuda, Jun Kondoh
article en

Abstract

Shear horizontal surface acoustic wave (SH-SAW) sensors are widely used in biosensing for marker detection and can also measure particle size. This study leverages SH-SAW technology with a reflective-type design and unique packaging technology to distinguish lipoprotein sizes on a 3 × 5 mm sensor chip, addressing the limitations of traditional, time-consuming methods like chromatography and nuclear magnetic resonance (NMR). A 250 MHz SH-SAW biosensor on 36° rotated Y-cut 90° X-propagating quartz substrates was used, with ApoA1, ApoB48, ApoB100, and Lp(a) antibodies immobilized on a gold surface to capture lipoproteins from human plasma. The ratio of velocity to attenuation changes, defined as the layer-parameter, was analyzed, and numerical calculations validated the experimental results. ApoA1-, ApoB48- and ApoB100-containing lipoproteins, as well as Lp(a), exhibited different sizes, with corresponding layer-parameter values of -0.398 ± 0.009, -1.133 ± 0.043, -0.661 ± 0.024, and -0.497 ± 0.035, respectively. These values demonstrated a strong correlation (<i>R</i> = 0.9987) between lipoprotein size and the increase in layer thickness. This study highlights that analyzing layer-parameters enables the estimation of lipoprotein size, thereby expanding the clinical potential of SH-SAW biosensors for point-of-care testing (POCT).

Lab on a ChipVol. 25(24)
Shizuoka University (JP)
Openalex Percentile: Top 85%
Acoustic Wave Resonator Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.