An Innovative LFC System Using a Fuzzy FOPID-Enhanced via PI Controller Tuned by the Catch Fish Optimization Algorithm Under Nonlinear Conditions

Load frequency control (LFC) remains a critical challenge in ensuring the stability of modern power grids. The integration of nonlinear dynamics into LFC design is paramount to achieving robust performance, which directly underpins grid reliability. This study introduces a novel hybrid control strategy—a fuzzy fractional-order proportional–integral–derivative (Fuzzy FOPID) controller augmented with a proportional–integral (PI) compensator—for LFC applications in two distinct dual-area interconnected power systems. To optimize the controller’s parameters, the recently developed Catch Fish Optimization Algorithm (CFOA) is employed, leveraging the Integral Time Absolute Error (ITAE) as the primary cost function for precision tuning. A comprehensive comparative analysis is conducted to benchmark the proposed controller against the existing methodologies documented in the literature. Nonlinear elements’ impact on the system stability is also investigated. The investigation evaluates the impact of critical nonlinearities, including governor dead band (GDB) and generation rate constraints (GRCs), on system performance. The simulation results demonstrate that the CFOA-tuned Fuzzy FOPID + PI controller exhibits superior robustness and dynamic response compared to conventional approaches, effectively mitigating frequency deviations and maintaining grid stability under nonlinear operating conditions. Furthermore, the CFOA demonstrates marginally superior convergence and tuning accuracy relative to the widely adopted Particle Swarm Optimization (PSO) algorithm. These findings underscore the proposed controller’s potential as a high-performance solution for real-world LFC systems, particularly in scenarios characterized by nonlinearities and interconnected grid complexities. This study advances the field by bridging the gap between fractional-order fuzzy control theory and practical power system applications, offering a validated strategy for enhancing grid resilience in dynamic environments.

Authors

Institutions

Publication Details

Journal
Sustainability
Published
2025-06-28
DOI
https://doi.org/10.3390/su17135966
Citations
4
Primary Topic
Frequency Control in Power Systems
Type
article
Field-Weighted Citation Impact
2.92
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An Innovative LFC System Using a Fuzzy FOPID-Enhanced via PI Controller Tuned by the Catch Fish Optimization Algorithm Under Nonlinear Conditions

Saif H. Almutairi, Mokhtar Shouran, Fatih Anayi, Michael Packianather
4 citations
Sustainability
Frequency Control in Power Systems
2.92
article

An Innovative LFC System Using a Fuzzy FOPID-Enhanced via PI Controller Tuned by the Catch Fish Optimization Algorithm Under Nonlinear Conditions

Saif H. Almutairi, Mokhtar Shouran, Fatih Anayi, Michael Packianather
article en
4 citations

Abstract

Load frequency control (LFC) remains a critical challenge in ensuring the stability of modern power grids. The integration of nonlinear dynamics into LFC design is paramount to achieving robust performance, which directly underpins grid reliability. This study introduces a novel hybrid control strategy—a fuzzy fractional-order proportional–integral–derivative (Fuzzy FOPID) controller augmented with a proportional–integral (PI) compensator—for LFC applications in two distinct dual-area interconnected power systems. To optimize the controller’s parameters, the recently developed Catch Fish Optimization Algorithm (CFOA) is employed, leveraging the Integral Time Absolute Error (ITAE) as the primary cost function for precision tuning. A comprehensive comparative analysis is conducted to benchmark the proposed controller against the existing methodologies documented in the literature. Nonlinear elements’ impact on the system stability is also investigated. The investigation evaluates the impact of critical nonlinearities, including governor dead band (GDB) and generation rate constraints (GRCs), on system performance. The simulation results demonstrate that the CFOA-tuned Fuzzy FOPID + PI controller exhibits superior robustness and dynamic response compared to conventional approaches, effectively mitigating frequency deviations and maintaining grid stability under nonlinear operating conditions. Furthermore, the CFOA demonstrates marginally superior convergence and tuning accuracy relative to the widely adopted Particle Swarm Optimization (PSO) algorithm. These findings underscore the proposed controller’s potential as a high-performance solution for real-world LFC systems, particularly in scenarios characterized by nonlinearities and interconnected grid complexities. This study advances the field by bridging the gap between fractional-order fuzzy control theory and practical power system applications, offering a validated strategy for enhancing grid resilience in dynamic environments.

SustainabilityVol. 17(13)
Libyan Academy (LY), Cardiff University (GB)
Openalex Percentile: Top 9%
Frequency Control in Power Systems
2.92
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.