COMBINED METRIC FOR EVALUATING THE QUALITY OF SYNTHESIZED BIOMEDICAL IMAGES

Context. This study addresses the problem of developing a new metric for evaluating the quality of synthesized images. The relevance of this problem is explained by the need for assessing the quality of artificially generated images. Additionally, the study highlights the potential of biomedical image synthesis based on diffusion models. The research results can be applied for biomedical image generation and quantitative quality assessment of synthesized images.Objective. The aim of this study is to develop a combined metric and an algorithm for biomedical image synthesis to assess the quality of synthesized images.Method. A combined metric MC for evaluating the quality of synthesized images is proposed. This metric is based on two existing metrics: MIS and MFID. Additionally, an algorithm for histopathological image synthesis using diffusion models has been developed.Results. To study the MIS, MFID, and MC metrics, histopathological images available on the Zenodo platform were used. This dataset contains three classes of histopathological images G1, G2, and G3, representing pathological conditions of breast tissue. Based on the developed image synthesis algorithm, three classes of artificial histopathological images were generated. Using the MIS, MFID, and MC metrics, quality assessments of the synthesized histopathological images were obtained. The developed metric will form the basis of a software module for image quality assessment using metrics. This software module will be integrated into CAD systems.Conclusions. A combined metric for evaluating the quality of synthesized images has been developed, along with a proposed algorithm for biomedical image synthesis. The software implementation of the combined metric and image synthesis algorithm has been integrated into an image quality assessment module.

Authors

Institutions

Publication Details

Journal
Radio Electronics Computer Science Control
Published
2025-06-29
DOI
https://doi.org/10.15588/1607-3274-2025-2-15
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

COMBINED METRIC FOR EVALUATING THE QUALITY OF SYNTHESIZED BIOMEDICAL IMAGES

Petro Liashchynskyi, Oleh Berezsky, G. M. Melnyk, M. O. Berezkyi et al.
Radio Electronics Computer Science Control
Advanced X-ray and CT Imaging
article

COMBINED METRIC FOR EVALUATING THE QUALITY OF SYNTHESIZED BIOMEDICAL IMAGES

Petro Liashchynskyi, Oleh Berezsky, G. M. Melnyk, M. O. Berezkyi, M. O. Dombrovskyi
article en

Abstract

Context. This study addresses the problem of developing a new metric for evaluating the quality of synthesized images. The relevance of this problem is explained by the need for assessing the quality of artificially generated images. Additionally, the study highlights the potential of biomedical image synthesis based on diffusion models. The research results can be applied for biomedical image generation and quantitative quality assessment of synthesized images.Objective. The aim of this study is to develop a combined metric and an algorithm for biomedical image synthesis to assess the quality of synthesized images.Method. A combined metric MC for evaluating the quality of synthesized images is proposed. This metric is based on two existing metrics: MIS and MFID. Additionally, an algorithm for histopathological image synthesis using diffusion models has been developed.Results. To study the MIS, MFID, and MC metrics, histopathological images available on the Zenodo platform were used. This dataset contains three classes of histopathological images G1, G2, and G3, representing pathological conditions of breast tissue. Based on the developed image synthesis algorithm, three classes of artificial histopathological images were generated. Using the MIS, MFID, and MC metrics, quality assessments of the synthesized histopathological images were obtained. The developed metric will form the basis of a software module for image quality assessment using metrics. This software module will be integrated into CAD systems.Conclusions. A combined metric for evaluating the quality of synthesized images has been developed, along with a proposed algorithm for biomedical image synthesis. The software implementation of the combined metric and image synthesis algorithm has been integrated into an image quality assessment module.

Radio Electronics Computer Science Control(2)
West Ukrainian National University (UA)
Openalex Percentile: Top 86%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.