Effects of Artificial Achilles Tendon on Hindlimb Movement Biomechanics and Muscle Morphology in Rabbits

Background/Objectives: Artificial tendons offer an alternative to biological tendon grafts and may restore normative biomechanical functions in humans and animals suffering segmental or complete tendon loss. The aim of this study was to quantify movement biomechanics during hopping gait and muscle properties of New Zealand White rabbits with a polyester silicone-coated (PET-SI) artificial tendon. Methods: In five rabbits, the biological Achilles tendon of the left hindlimb was surgically replaced with a PET-SI artificial tendon; five operated control rabbits underwent complete surgical excision of the biological Achilles tendon in the left hindlimb with no replacement (TE). Results: Across both groups at 2 and 8 weeks post-surgery compared to baseline, the maximum ankle angle during stance and swing phases of stride was significantly lower (i.e., more dorsiflexed) (p < 0.001), the peak vertical force was significantly higher (p < 0.001), and the average ground contact area was significantly lower (p < 0.001). At 8 weeks post-surgery, the muscle cross-sectional area of the lateral gastrocnemius was significantly higher in the PET-SI group than in the TE group (p = 0.006). Muscle mass and length were lower in the operated limb compared to the non-operated limb across the two groups (TE and PET-SI), with no significant differences between groups. Conclusions: The artificial Achilles tendon did not appear to provide superior biomechanical support during hopping compared to the TE group. However, the artificial tendon preserved muscle structural properties that correspond to the muscle’s capacity to generate force. Future studies should optimize the tendon–tissue interface.

Authors

Institutions

Publication Details

Journal
Biomechanics
Published
2025-07-01
DOI
https://doi.org/10.3390/biomechanics5030047
Primary Topic
Tendon Structure and Treatment
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effects of Artificial Achilles Tendon on Hindlimb Movement Biomechanics and Muscle Morphology in Rabbits

Dustin L. Crouch, David E. Anderson, Kristin M. Bowers, Madison M. Smith et al.
Biomechanics
Tendon Structure and Treatment
article

Effects of Artificial Achilles Tendon on Hindlimb Movement Biomechanics and Muscle Morphology in Rabbits

Dustin L. Crouch, David E. Anderson, Kristin M. Bowers, Madison M. Smith, Katrina L. Easton, Obinna P. Fidelis, Guilherme Pepino Bastos
article en

Abstract

Background/Objectives: Artificial tendons offer an alternative to biological tendon grafts and may restore normative biomechanical functions in humans and animals suffering segmental or complete tendon loss. The aim of this study was to quantify movement biomechanics during hopping gait and muscle properties of New Zealand White rabbits with a polyester silicone-coated (PET-SI) artificial tendon. Methods: In five rabbits, the biological Achilles tendon of the left hindlimb was surgically replaced with a PET-SI artificial tendon; five operated control rabbits underwent complete surgical excision of the biological Achilles tendon in the left hindlimb with no replacement (TE). Results: Across both groups at 2 and 8 weeks post-surgery compared to baseline, the maximum ankle angle during stance and swing phases of stride was significantly lower (i.e., more dorsiflexed) (p < 0.001), the peak vertical force was significantly higher (p < 0.001), and the average ground contact area was significantly lower (p < 0.001). At 8 weeks post-surgery, the muscle cross-sectional area of the lateral gastrocnemius was significantly higher in the PET-SI group than in the TE group (p = 0.006). Muscle mass and length were lower in the operated limb compared to the non-operated limb across the two groups (TE and PET-SI), with no significant differences between groups. Conclusions: The artificial Achilles tendon did not appear to provide superior biomechanical support during hopping compared to the TE group. However, the artificial tendon preserved muscle structural properties that correspond to the muscle’s capacity to generate force. Future studies should optimize the tendon–tissue interface.

BiomechanicsVol. 5(3)
Knoxville College (US), University of Tennessee at Knoxville (US)
National Institutes of Health
Openalex Percentile: Top 80%
Tendon Structure and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.