Achieving robust labeling above the circle of <scp>Willis</scp> with vessel‐encoded arterial spin labeling

Combining IOES with optimized PCASL parameters, the vessel-decoding efficacy in a region with complex vascular geometry above the CoW was improved. The automated encoding design process and scan times under 6 min make it feasible to observe flow patterns above the CoW in clinical settings, particularly for studies of collateral circulation.

Authors

Institutions

Publication Details

Journal
Magnetic Resonance in Medicine
Published
2025-07-01
DOI
https://doi.org/10.1002/mrm.30542
Citations
1
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
1.36

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Achieving robust labeling above the circle of Willis with vessel‐encoded arterial spin labeling

Tiansheng Qian, Zhensen Chen, Joseph G. Woods, Yang Ji et al.
1 citations
Magnetic Resonance in Medicine
Advanced MRI Techniques and Applications
1.36
article

Achieving robust labeling above the circle of Willis with vessel‐encoded arterial spin labeling

Tiansheng Qian, Zhensen Chen, Joseph G. Woods, Yang Ji, Yuriko Suzuki, Jian Wang, Thomas W. Okell, Hongwei Li, He Wang, Yujun Liao
article en
1 citations

Abstract

Combining IOES with optimized PCASL parameters, the vessel-decoding efficacy in a region with complex vascular geometry above the CoW was improved. The automated encoding design process and scan times under 6 min make it feasible to observe flow patterns above the CoW in clinical settings, particularly for studies of collateral circulation.

Magnetic Resonance in MedicineVol. 94(4)
University of Science and Technology of China (CN), Fudan University (CN), University of Oxford (GB), Shanghai Institute for Science of Science (CN), Nanjing Traditional Chinese Medicine Hospital (CN), Wellcome Centre for Integrative Neuroimaging (GB), Changzhou No.2 People's Hospital (CN), Huashan Hospital (CN), Shanghai Center for Brain Science and Brain-Inspired Technology (CN)
Natural Science Foundation of Shanghai, Wellcome Trust, Royal Society, National Natural Science Foundation of China, National Key Research and Development Program of China, NIHR Oxford Biomedical Research Centre
Openalex Percentile: Top 18%
Advanced MRI Techniques and Applications
1.36
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Achieving robust labeling above the circle of <scp>Willis</scp> with vessel‐encoded arterial spin labeling — Tiansheng Qian, Zhensen Chen, et al. · Magnetic Resonance in Medicine (2025) | TGRS Research Map | TGRS