Retrospective Analysis of accurate position of Different Implant Systems Using Mucosa-Supported Surgical Templates

Background: Accurate implant positioning is critical for long-term success in implant dentistry. Mucosa-supported surgical templates have gained popularity in edentulous cases due to their non-invasive nature and improved patient comfort. However, limited comparative data exist regarding their accuracy across different implant systems. This study retrospectively evaluates the positional accuracy of three commonly used implant systems when placed using mucosa-supported templates. Materials and Methods: This retrospective study included 45 edentulous patients (mean age: 61.3 ± 8.5 years) who underwent guided implant placement using mucosa-supported stereolithographic templates between 2020 and 2023. Three implant systems were analyzed: System A (n=15), System B (n=15), and System C (n=15). Pre- and postoperative CBCT scans were superimposed using digital planning software to measure deviations at the implant platform, apex, and angular discrepancies. Mean deviations were calculated and statistically analyzed using ANOVA and post hoc Tukey tests (significance set at p<0.05). Results: System A showed a mean coronal deviation of 1.45 ± 0.38 mm, apical deviation of 1.78 ± 0.52 mm, and angular deviation of 4.2° ± 1.1°.System B recorded a mean coronal deviation of 1.21 ± 0.33 mm, apical deviation of 1.55 ± 0.41 mm, and angular deviation of 3.5° ± 0.9°.System C had the lowest deviations, with coronal deviation at 1.02 ± 0.27 mm, apical deviation at 1.29 ± 0.36 mm, and angular deviation of 2.8° ± 0.7°.Statistical analysis showed significant differences between the systems (p<0.05), with System C demonstrating superior positional accuracy. Conclusion: Within the limitations of this retrospective study, System C exhibited significantly higher positioning accuracy when used with mucosa-supported surgical templates compared to Systems A and B. These findings underscore the importance of system-specific template compatibility and suggest that clinicians may achieve enhanced outcomes by selecting implant systems optimized for mucosa-supported guidance.

Authors

Publication Details

Journal
Journal of Neonatal Surgery
Published
2025-05-03
DOI
https://doi.org/10.63682/jns.v14i20s.5065
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Retrospective Analysis of accurate position of Different Implant Systems Using Mucosa-Supported Surgical Templates

Aaquib Nazir, Shashank Vijapure, Harsh Shah, Jewel Ipsita Sahani et al.
Journal of Neonatal Surgery
Dental Implant Techniques and Outcomes
article

Retrospective Analysis of accurate position of Different Implant Systems Using Mucosa-Supported Surgical Templates

Aaquib Nazir, Shashank Vijapure, Harsh Shah, Jewel Ipsita Sahani, Angel Aghera, Nidhi Senta
article en

Abstract

Background: Accurate implant positioning is critical for long-term success in implant dentistry. Mucosa-supported surgical templates have gained popularity in edentulous cases due to their non-invasive nature and improved patient comfort. However, limited comparative data exist regarding their accuracy across different implant systems. This study retrospectively evaluates the positional accuracy of three commonly used implant systems when placed using mucosa-supported templates. Materials and Methods: This retrospective study included 45 edentulous patients (mean age: 61.3 ± 8.5 years) who underwent guided implant placement using mucosa-supported stereolithographic templates between 2020 and 2023. Three implant systems were analyzed: System A (n=15), System B (n=15), and System C (n=15). Pre- and postoperative CBCT scans were superimposed using digital planning software to measure deviations at the implant platform, apex, and angular discrepancies. Mean deviations were calculated and statistically analyzed using ANOVA and post hoc Tukey tests (significance set at p<0.05). Results: System A showed a mean coronal deviation of 1.45 ± 0.38 mm, apical deviation of 1.78 ± 0.52 mm, and angular deviation of 4.2° ± 1.1°.System B recorded a mean coronal deviation of 1.21 ± 0.33 mm, apical deviation of 1.55 ± 0.41 mm, and angular deviation of 3.5° ± 0.9°.System C had the lowest deviations, with coronal deviation at 1.02 ± 0.27 mm, apical deviation at 1.29 ± 0.36 mm, and angular deviation of 2.8° ± 0.7°.Statistical analysis showed significant differences between the systems (p<0.05), with System C demonstrating superior positional accuracy. Conclusion: Within the limitations of this retrospective study, System C exhibited significantly higher positioning accuracy when used with mucosa-supported surgical templates compared to Systems A and B. These findings underscore the importance of system-specific template compatibility and suggest that clinicians may achieve enhanced outcomes by selecting implant systems optimized for mucosa-supported guidance.

Journal of Neonatal SurgeryVol. 14(20S)
Openalex Percentile: Top 78%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Retrospective Analysis of accurate position of Different Implant Systems Using Mucosa-Supported Surgical Templates — Aaquib Nazir, Shashank Vijapure, et al. · Journal of Neonatal Surgery (2025) | TGRS Research Map | TGRS