Dead or Alive? Identification of Postmortem Blood Through Detection of D-Dimer

At crime scenes, apart from the detection of blood, it may be important to determine whether a person was alive at the time of blood deposition. Based on the rapid onset of fibrinolysis after death, this pathway could be considered to identify potential biomarkers for postmortem blood. Fibrinolysis is the natural process that breaks down blood clots after healing a vascular injury. One of its products, D-dimer, could be a potential biomarker for postmortem blood. SERATEC<sup>®</sup> (SERATEC<sup>®</sup> GmbH, Göttingen, Germany) has developed the PMB immunochromatographic assay to simultaneously detect human hemoglobin and D-dimer. The main goals of this study were to assess the possibility of using this test to detect postmortem blood, evaluate D-dimer levels in antemortem, menstrual, and postmortem blood, and assess the ability to obtain STR profiles from postmortem blood. Except for one degraded sample, all postmortem blood samples reacted positively for the presence of D-dimer using the SERATEC<sup>®</sup> PMB test. All antemortem blood samples from living individuals showed negative results for D-dimer detection, except for one liquid sample with a weak positive result, probably due to pre-existing health conditions. Menstrual blood samples gave variable results for D-dimer. The DIMERTEST<sup>®</sup> Latex assay was used for semi-quantitative measurement of D-dimer concentrations, with postmortem and menstrual blood yielding higher D-dimer concentrations compared to antemortem blood. Full STR profiles were developed for all postmortem samples tested except for one degraded sample, pointing to the possibility of not only detecting postmortem blood at the crime scene but also the potential identification of the victim.

Authors

Institutions

Publication Details

Journal
Biology
Published
2025-06-28
DOI
https://doi.org/10.3390/biology14070784
Citations
1
Primary Topic
Forensic Toxicology and Drug Analysis
Type
article
Field-Weighted Citation Impact
1.31

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dead or Alive? Identification of Postmortem Blood Through Detection of D-Dimer

Gabriela Roca, Amy N. Brodeur, Sara C. Zapico, Gulnaz T. Javan et al.
1 citations
Biology
Forensic Toxicology and Drug Analysis
1.31
article

Dead or Alive? Identification of Postmortem Blood Through Detection of D-Dimer

Gabriela Roca, Amy N. Brodeur, Sara C. Zapico, Gulnaz T. Javan, TJ Tsai, Dakota Bell
article en
1 citations

Abstract

At crime scenes, apart from the detection of blood, it may be important to determine whether a person was alive at the time of blood deposition. Based on the rapid onset of fibrinolysis after death, this pathway could be considered to identify potential biomarkers for postmortem blood. Fibrinolysis is the natural process that breaks down blood clots after healing a vascular injury. One of its products, D-dimer, could be a potential biomarker for postmortem blood. SERATEC<sup>®</sup> (SERATEC<sup>®</sup> GmbH, Göttingen, Germany) has developed the PMB immunochromatographic assay to simultaneously detect human hemoglobin and D-dimer. The main goals of this study were to assess the possibility of using this test to detect postmortem blood, evaluate D-dimer levels in antemortem, menstrual, and postmortem blood, and assess the ability to obtain STR profiles from postmortem blood. Except for one degraded sample, all postmortem blood samples reacted positively for the presence of D-dimer using the SERATEC<sup>®</sup> PMB test. All antemortem blood samples from living individuals showed negative results for D-dimer detection, except for one liquid sample with a weak positive result, probably due to pre-existing health conditions. Menstrual blood samples gave variable results for D-dimer. The DIMERTEST<sup>®</sup> Latex assay was used for semi-quantitative measurement of D-dimer concentrations, with postmortem and menstrual blood yielding higher D-dimer concentrations compared to antemortem blood. Full STR profiles were developed for all postmortem samples tested except for one degraded sample, pointing to the possibility of not only detecting postmortem blood at the crime scene but also the potential identification of the victim.

BiologyVol. 14(7)
Smithsonian Institution (US), Boston University (US), New Jersey Institute of Technology (US), National Museum of Natural History (US), Alabama State University (US), Gesellschaft für Klinische Forschung (DE), Lone Star College (US)
National Institutes of Health
Peace, Justice and strong institutions
Openalex Percentile: Top 22%
Forensic Toxicology and Drug Analysis
1.31
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.