Optimal Scheduling of Multi-Storage Tank-Based Hydrogen Refueling Stations in Distribution Systems via Joint Power and Hydrogen Peak Shaving

In an integrated power–hydrogen distribution system (IPHDS), on-site hydrogen refueling stations (HRSs) with photovoltaic (PV) systems, battery energy storage systems, electrolyzers (ELs), fuel cells, and hydrogen storage tanks (HSTs) are key devices for maintaining reliable and cost-effective IPHDS operations via power peak shaving while supporting the charging demands of hydrogen vehicles (HVs). This study proposes an optimization framework that ensures profitable and robust operations of on-site HRSs under uncertainties in IPHDSs. Compared with conventional methods that manage IPHDS operation using single HST (S-HST)-based HRSs through only power peak shaving, the proposed method performs dual-peak shaving of power and hydrogen through substations and ELs in multiple HST (M-HST)-based HRSs, respectively. The proposed optimization framework is implemented using chance-constrained optimization (CCO) to address uncertainties in PV generation outputs and HV charging demands in IPHDSs. Furthermore, the proposed CCO framework includes constraints that adjust the predicted HV charging demand, thereby satisfying the actual HV charging demand for each predetermined scheduling period. Numerical examples conducted on IPHDSs (IEEE 33-node and 69-node power distribution systems with three and five on-site HRSs) show that, compared to a method with S-HST and only power peak shaving, the proposed CCO method with M-HST based on dual-peak shaving of power and hydrogen increases the total profit by 5.88% and 8.19% on average, respectively, under varying HV charging demand adjustment period and chance-constraint violation probability.

Authors

Institutions

Publication Details

Journal
IEEE Access
Published
2025-01-01
DOI
https://doi.org/10.1109/access.2025.3584881
Citations
2
Primary Topic
Hybrid Renewable Energy Systems
Type
article
Field-Weighted Citation Impact
1.06

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimal Scheduling of Multi-Storage Tank-Based Hydrogen Refueling Stations in Distribution Systems via Joint Power and Hydrogen Peak Shaving

Dae‐Hyun Choi, Sangyoon Lee, Md Mohaiminul Islam Mahin
2 citations
IEEE Access
Hybrid Renewable Energy Systems
1.06
article

Optimal Scheduling of Multi-Storage Tank-Based Hydrogen Refueling Stations in Distribution Systems via Joint Power and Hydrogen Peak Shaving

Dae‐Hyun Choi, Sangyoon Lee, Md Mohaiminul Islam Mahin
article en
2 citations

Abstract

In an integrated power–hydrogen distribution system (IPHDS), on-site hydrogen refueling stations (HRSs) with photovoltaic (PV) systems, battery energy storage systems, electrolyzers (ELs), fuel cells, and hydrogen storage tanks (HSTs) are key devices for maintaining reliable and cost-effective IPHDS operations via power peak shaving while supporting the charging demands of hydrogen vehicles (HVs). This study proposes an optimization framework that ensures profitable and robust operations of on-site HRSs under uncertainties in IPHDSs. Compared with conventional methods that manage IPHDS operation using single HST (S-HST)-based HRSs through only power peak shaving, the proposed method performs dual-peak shaving of power and hydrogen through substations and ELs in multiple HST (M-HST)-based HRSs, respectively. The proposed optimization framework is implemented using chance-constrained optimization (CCO) to address uncertainties in PV generation outputs and HV charging demands in IPHDSs. Furthermore, the proposed CCO framework includes constraints that adjust the predicted HV charging demand, thereby satisfying the actual HV charging demand for each predetermined scheduling period. Numerical examples conducted on IPHDSs (IEEE 33-node and 69-node power distribution systems with three and five on-site HRSs) show that, compared to a method with S-HST and only power peak shaving, the proposed CCO method with M-HST based on dual-peak shaving of power and hydrogen increases the total profit by 5.88% and 8.19% on average, respectively, under varying HV charging demand adjustment period and chance-constraint violation probability.

IEEE AccessVol. 13
Chonnam National University (KR), Chung-Ang University (KR)
National Research Foundation of Korea
Affordable and clean energy
Openalex Percentile: Top 20%
Hybrid Renewable Energy Systems
1.06
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.