Assessing workflow impact and clinical utility of AI-assisted brain aneurysm detection: A multi-reader study

Despite the plethora of AI-based algorithms developed for anomaly detection in radiology, subsequent integration into clinical setting is rarely evaluated. In this work, we assess the applicability and utility of an AI-based model for brain aneurysm detection comparing the performance of two readers with different levels of experience (2 and 13 years). We aim to answer the following questions: 1) Do the readers improve their performance when assisted by the AI algorithm? 2) How much does the AI algorithm impact routine clinical workflow? We reuse and enlarge our open-access, Time-Of-Flight Magnetic Resonance Angiography dataset (N = 460). We use 360 subjects for training/validating our algorithm and 100 as unseen test set for the reading session. Even though our model reaches state-of-the-art results on the test set (sensitivity = 74 %, false positive rate = 1.6), we show that neither the junior nor the senior reader significantly increase their sensitivity (p = 0.59, p = 1, respectively). In addition, we find that reading time for both readers is significantly higher in the "AI-assisted" setting than in the "Unassisted" (+15 s, on average; p=3×10<sup>-4</sup> junior, p=3×10<sup>-5</sup> senior). The confidence reported by the readers is unchanged across the two settings, indicating that the AI assistance does not influence the certainty of the diagnosis. Our findings highlight the importance of clinical validation of AI algorithms in a clinical setting involving radiologists. This study should serve as a reminder to the community to always examine the real-word effectiveness and workflow impact of proposed algorithms.

Authors

Institutions

Publication Details

Journal
NeuroImage Clinical
Published
2025-01-01
DOI
https://doi.org/10.1016/j.nicl.2025.103835
Primary Topic
Intracranial Aneurysms: Treatment and Complications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessing workflow impact and clinical utility of AI-assisted brain aneurysm detection: A multi-reader study

Guillaume Marie, Oscar Estéban, Guillaume Saliou, Ricardo Corredor‐Jerez et al.
NeuroImage Clinical
Intracranial Aneurysms: Treatment and Complications
article

Assessing workflow impact and clinical utility of AI-assisted brain aneurysm detection: A multi-reader study

Guillaume Marie, Oscar Estéban, Guillaume Saliou, Ricardo Corredor‐Jerez, Jonas Richiardi, Sébastien Tourbier, Meritxell Bach Cuadra, Sheryl A. Jankowski, Tommaso Di Noto, Francesco Puccinelli, Yasser Alemán‐Gómez, Patric Hagmann
article en

Abstract

Despite the plethora of AI-based algorithms developed for anomaly detection in radiology, subsequent integration into clinical setting is rarely evaluated. In this work, we assess the applicability and utility of an AI-based model for brain aneurysm detection comparing the performance of two readers with different levels of experience (2 and 13 years). We aim to answer the following questions: 1) Do the readers improve their performance when assisted by the AI algorithm? 2) How much does the AI algorithm impact routine clinical workflow? We reuse and enlarge our open-access, Time-Of-Flight Magnetic Resonance Angiography dataset (N = 460). We use 360 subjects for training/validating our algorithm and 100 as unseen test set for the reading session. Even though our model reaches state-of-the-art results on the test set (sensitivity = 74 %, false positive rate = 1.6), we show that neither the junior nor the senior reader significantly increase their sensitivity (p = 0.59, p = 1, respectively). In addition, we find that reading time for both readers is significantly higher in the "AI-assisted" setting than in the "Unassisted" (+15 s, on average; p=3×10<sup>-4</sup> junior, p=3×10<sup>-5</sup> senior). The confidence reported by the readers is unchanged across the two settings, indicating that the AI assistance does not influence the certainty of the diagnosis. Our findings highlight the importance of clinical validation of AI algorithms in a clinical setting involving radiologists. This study should serve as a reminder to the community to always examine the real-word effectiveness and workflow impact of proposed algorithms.

NeuroImage ClinicalVol. 47
Centre d'Imagerie BioMedicale (CH), Siemens Healthcare (United States) (US), École Polytechnique Fédérale de Lausanne (CH), University of Lausanne (CH)
National Science Foundation, Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung, Centre d'Imagerie BioMédicale
Openalex Percentile: Top 76%
Intracranial Aneurysms: Treatment and Complications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.