A parametric analysis of the earth air heat exchangers' thermal efficiency and their effect on surrounding soil over time

Earth Air Heat Exchanger (EAHE) system is widely regarded as an efficient and sustainable solution, minimizing the consumption of energy and enhancing indoor thermal comfort. This study seeks to conduct a detailed analysis of the parameters that affect the performance of EAHE systems, including the surrounding soil, climatic conditions, and time variations. A semi analytical numerical model was used and verified with existing literature data. Key parameters such as air velocity, operational periods, and soil thermal conductivity were investigated for their effect on the performance of the EAHE and the surrounding soil. The findings revealed that the model provided predictions that strongly agreed with experimental results, with only a 2.3% error margin. The study found that EAHE performance is predominantly influenced by higher soil conductivity and lower airflow velocity. In contrast, the duration of operation had minimal effect on the outlet air temperature, which increased by just 1 °C over 48 h compared to the 1st h. Lastly, the cooling of the surrounding atmosphere was identified as a key factor in enhancing the exchanger's efficiency, as it helps cool the soil after extended operation, thus restoring its cooling ability. Highlights EAHE outlet temp rose only 1 °C after 48 h continuous operation. Higher soil conductivity enhances heat transfer and cooling. Increased air velocity reduces heat exchange and cooling effect. Soil heats up over time, reducing EAHE performance without rest. Model was validated with just 2.3% error vs. experimental data.

Authors

Institutions

Publication Details

Journal
Journal of applied engineering science & technology.
Published
2025-04-12
DOI
https://doi.org/10.69717/jaest.v5.i1.111
Citations
1
Primary Topic
Geothermal Energy Systems and Applications
Type
article
Field-Weighted Citation Impact
0.36
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A parametric analysis of the earth air heat exchangers' thermal efficiency and their effect on surrounding soil over time

Charafeddine Beldjani, Mohamed Aymen Kethiri, Nora Boultif, Müslüm Arıcı et al.
1 citations
Journal of applied engineering science & technology.
Geothermal Energy Systems and Applications
0.36
article

A parametric analysis of the earth air heat exchangers' thermal efficiency and their effect on surrounding soil over time

Charafeddine Beldjani, Mohamed Aymen Kethiri, Nora Boultif, Müslüm Arıcı, Yousra Boutera, Noureddine Moummi, Saleh Momen SM
article en
1 citations

Abstract

Earth Air Heat Exchanger (EAHE) system is widely regarded as an efficient and sustainable solution, minimizing the consumption of energy and enhancing indoor thermal comfort. This study seeks to conduct a detailed analysis of the parameters that affect the performance of EAHE systems, including the surrounding soil, climatic conditions, and time variations. A semi analytical numerical model was used and verified with existing literature data. Key parameters such as air velocity, operational periods, and soil thermal conductivity were investigated for their effect on the performance of the EAHE and the surrounding soil. The findings revealed that the model provided predictions that strongly agreed with experimental results, with only a 2.3% error margin. The study found that EAHE performance is predominantly influenced by higher soil conductivity and lower airflow velocity. In contrast, the duration of operation had minimal effect on the outlet air temperature, which increased by just 1 °C over 48 h compared to the 1st h. Lastly, the cooling of the surrounding atmosphere was identified as a key factor in enhancing the exchanger's efficiency, as it helps cool the soil after extended operation, thus restoring its cooling ability. Highlights EAHE outlet temp rose only 1 °C after 48 h continuous operation. Higher soil conductivity enhances heat transfer and cooling. Increased air velocity reduces heat exchange and cooling effect. Soil heats up over time, reducing EAHE performance without rest. Model was validated with just 2.3% error vs. experimental data.

Journal of applied engineering science & technology.Vol. 5(1)
University of Biskra (DZ), Kocaeli Üniversitesi (TR)
Openalex Percentile: Top 42%
Geothermal Energy Systems and Applications
0.36
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.