QC Approaches for an Odor Measurement Method Using SIFT-MS Real Time Monitoring System, Determination of the MDL and Application

The SIFT-MS measurement system is a new useful analytical tool for odor analysis due to its high sensitivity detection and quantification of multiple odorants simultaneously in real time. However, the Korean analytical standard technique lacks a QA/QC methodology for real-time measurement. In this study, three distinct Method Detection Limit (MDL) estimation procedures were evaluated to determine the optimal quality control strategy for the SIFT-MS real-time analytical method: (1) MDLs created with spiked samples, (2) MDLb based on method blanks, and (3) LOD provided in the instrument operating manual. The results revealed that the MDLs were the most significant of the three estimated results, followed by the MDLb and the LOD. The US EPA procedure recommends selecting the greater value, which in this study corresponds to the MDLs; however, the absence of gas-phase CRMs for 18 out of the 22 odor compounds limited the applicability of MDLs. As a result, we selected the MDLb estimation based on ambient background air as the most appropriate approach for determining the MDL in the real-time monitoring system. In 2024, monitoring data obtained using the SIFT-MS measurement system in a casting industrial complex in Gyeongsangnam-do revealed that hydrogen sulfide, toluene, acetaldehyde, and xylenes are the key management target compounds of the odor emission sources.

Authors

Publication Details

Journal
Journal of Environmental Analysis Health and Toxicology
Published
2025-06-30
DOI
https://doi.org/10.36278/jeaht.28.2.92
Primary Topic
Advanced Chemical Sensor Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

QC Approaches for an Odor Measurement Method Using SIFT-MS Real Time Monitoring System, Determination of the MDL and Application

Inho Jeong, Gye-Hwan Kim, Seong-Jae Park, Dongho Lee
Journal of Environmental Analysis Health and Toxicology
Advanced Chemical Sensor Technologies
article

QC Approaches for an Odor Measurement Method Using SIFT-MS Real Time Monitoring System, Determination of the MDL and Application

Inho Jeong, Gye-Hwan Kim, Seong-Jae Park, Dongho Lee
article en

Abstract

The SIFT-MS measurement system is a new useful analytical tool for odor analysis due to its high sensitivity detection and quantification of multiple odorants simultaneously in real time. However, the Korean analytical standard technique lacks a QA/QC methodology for real-time measurement. In this study, three distinct Method Detection Limit (MDL) estimation procedures were evaluated to determine the optimal quality control strategy for the SIFT-MS real-time analytical method: (1) MDLs created with spiked samples, (2) MDLb based on method blanks, and (3) LOD provided in the instrument operating manual. The results revealed that the MDLs were the most significant of the three estimated results, followed by the MDLb and the LOD. The US EPA procedure recommends selecting the greater value, which in this study corresponds to the MDLs; however, the absence of gas-phase CRMs for 18 out of the 22 odor compounds limited the applicability of MDLs. As a result, we selected the MDLb estimation based on ambient background air as the most appropriate approach for determining the MDL in the real-time monitoring system. In 2024, monitoring data obtained using the SIFT-MS measurement system in a casting industrial complex in Gyeongsangnam-do revealed that hydrogen sulfide, toluene, acetaldehyde, and xylenes are the key management target compounds of the odor emission sources.

Journal of Environmental Analysis Health and ToxicologyVol. 28(2)
Openalex Percentile: Top 86%
Advanced Chemical Sensor Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

QC Approaches for an Odor Measurement Method Using SIFT-MS Real Time Monitoring System, Determination of the MDL and Application — Inho Jeong, Gye-Hwan Kim, et al. · Journal of Environmental Analysis Health and Toxicology (2025) | TGRS Research Map | TGRS