Study of Aldehyde Analysis in Flue Gas Using HPLC-HRMS

Aldehydes are among the major air pollutants due to their contribution to photochemical smog, health hazards, and odor. However, few studies have examined aldehyde concentration levels in flue gas, and only a limited number of substances have established emission limits. In this study, a method for the analysis of 14 aldehydes using HPLC-HRMS was optimized, and aldehyde concentrations in flue gas were measured. The optimized method for target substance qualification and quantification demonstrated linearity within a calibration range of 5-100 ng/mL, recoveries of 84-104 %, and precision ranging from 1-9 %. The method detection limit(MDL) for each compound ranged from 0.067-0.377 ng/mL, and the limit of quantification(LOQ) ranged from 0.212-1.202 ng/mL. In the flue gas samples, formaldehyde and acetaldehyde were detected in all stacks, but their concentrations remained within emission limits. However, many substances without established emission limits were also detected, with detection patterns varying by workplace. It appears necessary to characterize workplace types and implement tailored management strategies. The data collected in this study on aldehyde emissions in flue gas can support the identification of workplace-specific characteristics and the establishment of management standards.

Authors

Publication Details

Journal
Journal of Environmental Analysis Health and Toxicology
Published
2025-06-30
DOI
https://doi.org/10.36278/jeaht.28.2.72
Primary Topic
Advanced Chemical Sensor Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study of Aldehyde Analysis in Flue Gas Using HPLC-HRMS

Junho Jeon, Soyoung Lee
Journal of Environmental Analysis Health and Toxicology
Advanced Chemical Sensor Technologies
article

Study of Aldehyde Analysis in Flue Gas Using HPLC-HRMS

Junho Jeon, Soyoung Lee
article en

Abstract

Aldehydes are among the major air pollutants due to their contribution to photochemical smog, health hazards, and odor. However, few studies have examined aldehyde concentration levels in flue gas, and only a limited number of substances have established emission limits. In this study, a method for the analysis of 14 aldehydes using HPLC-HRMS was optimized, and aldehyde concentrations in flue gas were measured. The optimized method for target substance qualification and quantification demonstrated linearity within a calibration range of 5-100 ng/mL, recoveries of 84-104 %, and precision ranging from 1-9 %. The method detection limit(MDL) for each compound ranged from 0.067-0.377 ng/mL, and the limit of quantification(LOQ) ranged from 0.212-1.202 ng/mL. In the flue gas samples, formaldehyde and acetaldehyde were detected in all stacks, but their concentrations remained within emission limits. However, many substances without established emission limits were also detected, with detection patterns varying by workplace. It appears necessary to characterize workplace types and implement tailored management strategies. The data collected in this study on aldehyde emissions in flue gas can support the identification of workplace-specific characteristics and the establishment of management standards.

Journal of Environmental Analysis Health and ToxicologyVol. 28(2)
Openalex Percentile: Top 86%
Advanced Chemical Sensor Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.