On‐Design and Off‐Design Performance of Variable Area Ejectors: A Comparative Study of Constant Rate of Momentum Change and Constant Rate of Kinetic Energy Change Methods

ABSTRACT The design of the ejector is crucial, as the overall performance and efficiency of the system depend on its internal geometry, dimensions, and flow characteristics. The present experimental study compares the performance of variable area ejectors developed based on the “constant rate of momentum change (CRMC)” and “constant rate of kinetic energy change (CRKEC).” The pressure recovery ratio (PRR) and entrainment ratio ( ω ) at on‐design operating conditions were computed based on experimental results. The study also optimizes both the ejector's entrainment ratio at off‐design conditions and the impact of nozzle exit positions. CRMC ejectors provide higher entrainment ratios (0.512) and lower PRRs (0.178), while CRKEC ejectors provide slightly higher PRRs (0.18) and lower entrainment ratios (0.5) at on‐design conditions. The results indicate that both variable‐area ejectors based on CRMC and CRKEC have their own advantages and limitations regarding performance and suitability for specific applications.

Authors

Institutions

Publication Details

Journal
Heat Transfer
Published
2025-06-29
DOI
https://doi.org/10.1002/htj.70013
Primary Topic
Refrigeration and Air Conditioning Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

On‐Design and Off‐Design Performance of Variable Area Ejectors: A Comparative Study of Constant Rate of Momentum Change and Constant Rate of Kinetic Energy Change Methods

P.M.V. Subbarao, Virendra Kumar
Heat Transfer
Refrigeration and Air Conditioning Technologies
article

On‐Design and Off‐Design Performance of Variable Area Ejectors: A Comparative Study of Constant Rate of Momentum Change and Constant Rate of Kinetic Energy Change Methods

P.M.V. Subbarao, Virendra Kumar
article en

Abstract

ABSTRACT The design of the ejector is crucial, as the overall performance and efficiency of the system depend on its internal geometry, dimensions, and flow characteristics. The present experimental study compares the performance of variable area ejectors developed based on the “constant rate of momentum change (CRMC)” and “constant rate of kinetic energy change (CRKEC).” The pressure recovery ratio (PRR) and entrainment ratio ( ω ) at on‐design operating conditions were computed based on experimental results. The study also optimizes both the ejector's entrainment ratio at off‐design conditions and the impact of nozzle exit positions. CRMC ejectors provide higher entrainment ratios (0.512) and lower PRRs (0.178), while CRKEC ejectors provide slightly higher PRRs (0.18) and lower entrainment ratios (0.5) at on‐design conditions. The results indicate that both variable‐area ejectors based on CRMC and CRKEC have their own advantages and limitations regarding performance and suitability for specific applications.

Heat TransferVol. 54(7)
Madan Mohan Malaviya University of Technology (IN), Indian Institute of Technology Delhi (IN)
Openalex Percentile: Top 85%
Refrigeration and Air Conditioning Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.