The Experimental Study of Reducing Cooling Fan Noise Using Test Bench

The blade pass frequency (BPF) noise for axial flow cooling fans in Electrical Vehicles (EV) is much obvious in some of rotational speeds. The root cause of this BPF noise is due to the cooling fan loading which is caused by the pressure difference between inlet and outlet of the fan. The pressure difference is defined as the resistance value of the fan. The resistance value of fan in EVs is much higher than the value of internal-combustion engine (ICE) vehicles. It is very difficult to obtain the resistance value in full vehicle condition. A new method to estimate the vehicle resistance value is developed using bench tests. By assuming, on the same operating parameters of the same fan both in vehicle and in test bench, such as inlet voltage, current and rotational speed, the resistance value of the fan in vehicle is the same as in test bench, thus, the operating parameters are used in the bench testing to simulate the resistance value of the fan in vehicle. Once the resistance value is achieved, the noise values of the fan can be measured in the test bench under different rotational speeds. Several testing results of different fans show that the BPF noises in bench with the defined resistance value align with those in vehicle. Using this method, the cooling fan noise can be studied in bench, earlier fan prototypes can be evaluated before finalizing design parameters. From this study it is found that the deformation of blades under the operation is the main factor to affect BPF noise levels. During operation the blade deformation changes the gap between the blade and the shroud in axial direction. The gap is related to the initial gap and the strengthen of the fan blade. This gap can be designed and optimized to balance the BPF noise in the total rotational range. The guidelines for designing low noise fan are outlined in this paper also.

Authors

Institutions

Publication Details

Journal
International Journal of Mechanical Engineering and Applications
Published
2025-06-16
DOI
https://doi.org/10.11648/j.ijmea.20251303.12
Primary Topic
Aerodynamics and Acoustics in Jet Flows
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Experimental Study of Reducing Cooling Fan Noise Using Test Bench

Chengyu Duan, Perry Gu, Jing Yu, Changshui Zhou et al.
International Journal of Mechanical Engineering and Applications
Aerodynamics and Acoustics in Jet Flows
article

The Experimental Study of Reducing Cooling Fan Noise Using Test Bench

Chengyu Duan, Perry Gu, Jing Yu, Changshui Zhou, Siyuan Shao, Dai Haijiang
article en

Abstract

The blade pass frequency (BPF) noise for axial flow cooling fans in Electrical Vehicles (EV) is much obvious in some of rotational speeds. The root cause of this BPF noise is due to the cooling fan loading which is caused by the pressure difference between inlet and outlet of the fan. The pressure difference is defined as the resistance value of the fan. The resistance value of fan in EVs is much higher than the value of internal-combustion engine (ICE) vehicles. It is very difficult to obtain the resistance value in full vehicle condition. A new method to estimate the vehicle resistance value is developed using bench tests. By assuming, on the same operating parameters of the same fan both in vehicle and in test bench, such as inlet voltage, current and rotational speed, the resistance value of the fan in vehicle is the same as in test bench, thus, the operating parameters are used in the bench testing to simulate the resistance value of the fan in vehicle. Once the resistance value is achieved, the noise values of the fan can be measured in the test bench under different rotational speeds. Several testing results of different fans show that the BPF noises in bench with the defined resistance value align with those in vehicle. Using this method, the cooling fan noise can be studied in bench, earlier fan prototypes can be evaluated before finalizing design parameters. From this study it is found that the deformation of blades under the operation is the main factor to affect BPF noise levels. During operation the blade deformation changes the gap between the blade and the shroud in axial direction. The gap is related to the initial gap and the strengthen of the fan blade. This gap can be designed and optimized to balance the BPF noise in the total rotational range. The guidelines for designing low noise fan are outlined in this paper also.

International Journal of Mechanical Engineering and ApplicationsVol. 13(3)
Chery Automobile (China) (CN)
Openalex Percentile: Top 79%
Aerodynamics and Acoustics in Jet Flows
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.