A Shear Wall Design Study in an 8-Story Building

Indonesia is an earthquake-prone region. These natural disasters have caused buildings to collapse and claimed many lives, highlighting the need for earthquake-resistant design. Faculty of Engineering (FE) of Universitas Sriwijaya plan to build an earthquake-resistant 8-story building functioning as classrooms and office. The problem is how to determine the appropriate structural system between SMRF alone or a combined SMRF-SRCSW system and how to determine the optimal position of the shear wall without disturbing the existing layout in the FE Tower.This research method employed a simulation experiment using six models of FE Tower. The Model was analyzed using software to obtain fundamental vibration period, mode shape, soft story check, torsional irregularity check, and the concrete structure design analysis.Software analysis results indicate that the FE Tower exhibits both vertical and horizontal geometric irregularities, necessitating dilatation for simplification. The structural system used in this design combines SMRF and SRCSW, and the optimal position of the shear wall is positioned on the outer wall and corner of the building.

Authors

Institutions

Publication Details

Journal
Journal of Architectural Design and Urbanism
Published
2025-06-18
DOI
https://doi.org/10.14710/jadu.v7i2.26117
Primary Topic
Seismic Performance and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Shear Wall Design Study in an 8-Story Building

Livian Teddy, Hanny Hosiana Tumbelaka
Journal of Architectural Design and Urbanism
Seismic Performance and Analysis
article

A Shear Wall Design Study in an 8-Story Building

Livian Teddy, Hanny Hosiana Tumbelaka
article en

Abstract

Indonesia is an earthquake-prone region. These natural disasters have caused buildings to collapse and claimed many lives, highlighting the need for earthquake-resistant design. Faculty of Engineering (FE) of Universitas Sriwijaya plan to build an earthquake-resistant 8-story building functioning as classrooms and office. The problem is how to determine the appropriate structural system between SMRF alone or a combined SMRF-SRCSW system and how to determine the optimal position of the shear wall without disturbing the existing layout in the FE Tower.This research method employed a simulation experiment using six models of FE Tower. The Model was analyzed using software to obtain fundamental vibration period, mode shape, soft story check, torsional irregularity check, and the concrete structure design analysis.Software analysis results indicate that the FE Tower exhibits both vertical and horizontal geometric irregularities, necessitating dilatation for simplification. The structural system used in this design combines SMRF and SRCSW, and the optimal position of the shear wall is positioned on the outer wall and corner of the building.

Journal of Architectural Design and UrbanismVol. 7(2)
Petra Christian University (ID), Sriwijaya University (ID)
Openalex Percentile: Top 84%
Seismic Performance and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A Shear Wall Design Study in an 8-Story Building — Livian Teddy, Hanny Hosiana Tumbelaka · Journal of Architectural Design and Urbanism (2025) | TGRS Research Map | TGRS