Comparison of Teat End Massage Characteristics Across Liner Types Using a Modeling Device

This study evaluated teat end massages (TEMs) associated with various liner shapes and provides foundational data for assessing the impact of liner design on teat ends. A silicon dropper, simulating a teat end, was attached to one end of a stainless tube, with a pressure sensor attached to the opposite end. Twelve liner types were tested under vacuum settings of 40 or 50 kPa, with liners positioned at depths of 7 and 10 cm from the liner mouthpiece. TEMs were recorded over 10-s periods at 0.1-s intervals. TEMs were also conducted after altering the pulsation ratio. TEMs were consistently higher at 50 kPa for all liners and increased at a depth of 10 cm compared with 7 cm. Significant differences (p < 0.01) in TEMs were observed across four categories of liner types, with non-round liners exhibiting higher TEMs. The D-phase duration was correlated with average TEMs, but not with maximum TEMs. Based on these findings, the study recommends using either a round liner with outer ribs or a round silicone liner with a pulsation ratio of 60:40 to promote teat end health.

Authors

Publication Details

Journal
Animal Science Journal
Published
2025-01-01
DOI
https://doi.org/10.1111/asj.70078
Primary Topic
Infant Health and Development
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of Teat End Massage Characteristics Across Liner Types Using a Modeling Device

Masafumi Enokidani
Animal Science Journal
Infant Health and Development
article

Comparison of Teat End Massage Characteristics Across Liner Types Using a Modeling Device

Masafumi Enokidani
article en

Abstract

This study evaluated teat end massages (TEMs) associated with various liner shapes and provides foundational data for assessing the impact of liner design on teat ends. A silicon dropper, simulating a teat end, was attached to one end of a stainless tube, with a pressure sensor attached to the opposite end. Twelve liner types were tested under vacuum settings of 40 or 50 kPa, with liners positioned at depths of 7 and 10 cm from the liner mouthpiece. TEMs were recorded over 10-s periods at 0.1-s intervals. TEMs were also conducted after altering the pulsation ratio. TEMs were consistently higher at 50 kPa for all liners and increased at a depth of 10 cm compared with 7 cm. Significant differences (p < 0.01) in TEMs were observed across four categories of liner types, with non-round liners exhibiting higher TEMs. The D-phase duration was correlated with average TEMs, but not with maximum TEMs. Based on these findings, the study recommends using either a round liner with outer ribs or a round silicone liner with a pulsation ratio of 60:40 to promote teat end health.

Animal Science JournalVol. 96(1)
Forskningsrådet om Hälsa, Arbetsliv och Välfärd
Openalex Percentile: Top 74%
Infant Health and Development
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Comparison of Teat End Massage Characteristics Across Liner Types Using a Modeling Device — Masafumi Enokidani · Animal Science Journal (2025) | TGRS Research Map | TGRS