Determination of nitrate concentration in water by multispectral UV analysis

This study presents the results of the development, calibration, and testing of an experimental prototype of a portable system for determining nitrate concentrations in water based on multispectral ultraviolet analysis combined with machine learning algorithms. The urgency of the problem lies in the widespread nitrate pollution of natural and drinking water caused by excessive use of nitrogen fertilizers, wastewater discharges, and natural leaching processes. High nitrate concentrations pose serious health threats, especially to infants, leading to methemoglobinemia and contributing to chronic diseases. Therefore, there is a critical need for autonomous solutions capable of providing rapid and accurate water quality analysis without complex laboratory procedures or chemical reagents. The proposed system uses four UV LEDs with wavelengths of 265, 308, 365, and 395 nm. Each channel serves a specific function: 308 nm detects nitrates, 265 nm monitors organic background, 365 nm tracks turbidity, and 395 nm is used for measurement stability control. The optical system is built on a photodiode in photoconductive mode with a transimpedance amplifier. An automatic delay algorithm was implemented to avoid measurements under unstable sample conditions based on signal fluctuations in the 395 nm channel. Differential processing of spectral data (A308−A265, A308/A265), combined with a Random Forest regression model, enabled accurate nitrate quantification up to 300 mg/L. The model achieved a high correlation (R² = 0.9806) and a mean absolute error of 0.77 mg/L. This approach effectively compensates for background interference and deviations from the Beer–Lambert–Bouguer law through adaptive mathematical modeling. The proposed system is suitable for implementation in mobile field instruments, environmental monitoring stations, agricultural infrastructure, and household water testing. Future work includes expanding the number of channels, integrating pH and conductivity sensors, and adapting the method for more complex multicomponent environments.

Authors

Publication Details

Journal
Bulletin of Kyiv Polytechnic Institute Series Instrument Making
Published
2025-06-28
DOI
https://doi.org/10.20535/1970.69(1).2025.331822
Primary Topic
Water Quality Monitoring and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Determination of nitrate concentration in water by multispectral UV analysis

Наталія ЗАЩЕПКІНА, Dmytro Melnychenko
Bulletin of Kyiv Polytechnic Institute Series Instrument Making
Water Quality Monitoring and Analysis
article

Determination of nitrate concentration in water by multispectral UV analysis

Наталія ЗАЩЕПКІНА, Dmytro Melnychenko
article en

Abstract

This study presents the results of the development, calibration, and testing of an experimental prototype of a portable system for determining nitrate concentrations in water based on multispectral ultraviolet analysis combined with machine learning algorithms. The urgency of the problem lies in the widespread nitrate pollution of natural and drinking water caused by excessive use of nitrogen fertilizers, wastewater discharges, and natural leaching processes. High nitrate concentrations pose serious health threats, especially to infants, leading to methemoglobinemia and contributing to chronic diseases. Therefore, there is a critical need for autonomous solutions capable of providing rapid and accurate water quality analysis without complex laboratory procedures or chemical reagents. The proposed system uses four UV LEDs with wavelengths of 265, 308, 365, and 395 nm. Each channel serves a specific function: 308 nm detects nitrates, 265 nm monitors organic background, 365 nm tracks turbidity, and 395 nm is used for measurement stability control. The optical system is built on a photodiode in photoconductive mode with a transimpedance amplifier. An automatic delay algorithm was implemented to avoid measurements under unstable sample conditions based on signal fluctuations in the 395 nm channel. Differential processing of spectral data (A308−A265, A308/A265), combined with a Random Forest regression model, enabled accurate nitrate quantification up to 300 mg/L. The model achieved a high correlation (R² = 0.9806) and a mean absolute error of 0.77 mg/L. This approach effectively compensates for background interference and deviations from the Beer–Lambert–Bouguer law through adaptive mathematical modeling. The proposed system is suitable for implementation in mobile field instruments, environmental monitoring stations, agricultural infrastructure, and household water testing. Future work includes expanding the number of channels, integrating pH and conductivity sensors, and adapting the method for more complex multicomponent environments.

Bulletin of Kyiv Polytechnic Institute Series Instrument Making(69(1))
Openalex Percentile: Top 81%
Water Quality Monitoring and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.