Studying the chromatographic separation of caffeine, theophylline, and theobromine

Theobromine, theophylline, and caffeine retention times in a C18 HPLC column (stationary phase) were investigated as a function of mobile phase flow rate, mobile phase composition, and column temperature. When the mobile phase flow rate increased from 0.1 to 1 mL/min and the methanol concentration increased from 5 to 30%, the retention time and peak width of these three compounds were found to be reduced. While there was a small influence of increasing the mobile phase flow rate on the resolution, decreasing the methanol concentration in the mobile phase considerably reduced the resolution. In addition, the mobile phase flow rate and composition were determined to have a more significant impact than the column temperature. According to the findings, theobromine, theophylline, and caffeine were most effectively separated by liquid chromatography at a flow rate of 0.5 mL/min with a mobile phase methanol concentration of 15%.

Authors

Institutions

Publication Details

Journal
Iraqi Journal of Chemical and Petroleum Engineering
Published
2025-06-30
DOI
https://doi.org/10.31699/ijcpe.2025.2.15
Primary Topic
Analytical Chemistry and Chromatography
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Studying the chromatographic separation of caffeine, theophylline, and theobromine

Miqat Hasan Salih, Hassanain A. Hassan, Maha H. Al-Hassani
Iraqi Journal of Chemical and Petroleum Engineering
Analytical Chemistry and Chromatography
article

Studying the chromatographic separation of caffeine, theophylline, and theobromine

Miqat Hasan Salih, Hassanain A. Hassan, Maha H. Al-Hassani
article en

Abstract

Theobromine, theophylline, and caffeine retention times in a C18 HPLC column (stationary phase) were investigated as a function of mobile phase flow rate, mobile phase composition, and column temperature. When the mobile phase flow rate increased from 0.1 to 1 mL/min and the methanol concentration increased from 5 to 30%, the retention time and peak width of these three compounds were found to be reduced. While there was a small influence of increasing the mobile phase flow rate on the resolution, decreasing the methanol concentration in the mobile phase considerably reduced the resolution. In addition, the mobile phase flow rate and composition were determined to have a more significant impact than the column temperature. According to the findings, theobromine, theophylline, and caffeine were most effectively separated by liquid chromatography at a flow rate of 0.5 mL/min with a mobile phase methanol concentration of 15%.

Iraqi Journal of Chemical and Petroleum EngineeringVol. 26(2)
University of Baghdad (IQ)
Openalex Percentile: Top 86%
Analytical Chemistry and Chromatography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Studying the chromatographic separation of caffeine, theophylline, and theobromine — Miqat Hasan Salih, Hassanain A. Hassan, et al. · Iraqi Journal of Chemical and Petroleum Engineering (2025) | TGRS Research Map | TGRS