Relationship Between Effective Dose, Alternative Metrics, and SSDE: Experiences with Two CT Dose-Monitoring Systems

<b>Background</b>: We assessed the frequency and causes of discrepancies in CT dose indices such as dose-length product (DLP), size-specific dose estimate (SSDE), and effective dose (ED), as calculated by CT dose-monitoring systems. Our secondary aim was to demonstrate the estimation of size-specific ED (SED) from the patients' dose records. <b>Methods</b>: The retrospective study included dosimetric data of 79,383 consecutive CT exams performed on two CT scanners. The following dose values were recorded from both the locally developed dose-monitoring system (DMS) and a commercial dose-monitoring program (DW<sup>TM</sup>): DLP, SSDE, and ED. Only the DMS provided bodyweight-corrected effective dose (SED<sub>DMS</sub>) and the SED based on previous published data. <b>Results</b>: Without body-region-specific analysis, there were no tendentious differences between the DLP, ED, or SSDE values obtained from DW<sup>TM</sup> and DMS. However, the body region-based correlation revealed substantial differences between ED<sub>DMS</sub> and ED<sub>DW</sub>, primarily related to inadequate identification of the body. SSDE showed strong correlation to each anatomical category and CT device, except for the head region, where inadequate consideration of CT inclination was the reason for the biased SSDE<sub>DW</sub> value. Furthermore, by analyzing the SED<sub>DMS</sub>, SSDE, and SED correlations, we concluded that SED<sub>DMS</sub> is a promising figure for estimating the SED value. <b>Conclusions</b>: SED provides suitable supplementary size-specific dose data to SDDE and may be a preferable choice for estimating cumulative doses in routine radiological practice.

Authors

Institutions

Publication Details

Journal
Diagnostics
Published
2025-06-28
DOI
https://doi.org/10.3390/diagnostics15131654
Citations
1
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
1.36

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Relationship Between Effective Dose, Alternative Metrics, and SSDE: Experiences with Two CT Dose-Monitoring Systems

Ervin Berényi, Zsolt Dankó, János Kiss, Mária Marosi et al.
1 citations
Diagnostics
Radiation Dose and Imaging
1.36
article

Relationship Between Effective Dose, Alternative Metrics, and SSDE: Experiences with Two CT Dose-Monitoring Systems

Ervin Berényi, Zsolt Dankó, János Kiss, Mária Marosi, László Urbán, Zita Képes, Miklós Emri, Ervin Balázs, Lilla Szatmáriné Egeresi, Péter Bágyi, László Balkay
article en
1 citations

Abstract

<b>Background</b>: We assessed the frequency and causes of discrepancies in CT dose indices such as dose-length product (DLP), size-specific dose estimate (SSDE), and effective dose (ED), as calculated by CT dose-monitoring systems. Our secondary aim was to demonstrate the estimation of size-specific ED (SED) from the patients' dose records. <b>Methods</b>: The retrospective study included dosimetric data of 79,383 consecutive CT exams performed on two CT scanners. The following dose values were recorded from both the locally developed dose-monitoring system (DMS) and a commercial dose-monitoring program (DW<sup>TM</sup>): DLP, SSDE, and ED. Only the DMS provided bodyweight-corrected effective dose (SED<sub>DMS</sub>) and the SED based on previous published data. <b>Results</b>: Without body-region-specific analysis, there were no tendentious differences between the DLP, ED, or SSDE values obtained from DW<sup>TM</sup> and DMS. However, the body region-based correlation revealed substantial differences between ED<sub>DMS</sub> and ED<sub>DW</sub>, primarily related to inadequate identification of the body. SSDE showed strong correlation to each anatomical category and CT device, except for the head region, where inadequate consideration of CT inclination was the reason for the biased SSDE<sub>DW</sub> value. Furthermore, by analyzing the SED<sub>DMS</sub>, SSDE, and SED correlations, we concluded that SED<sub>DMS</sub> is a promising figure for estimating the SED value. <b>Conclusions</b>: SED provides suitable supplementary size-specific dose data to SDDE and may be a preferable choice for estimating cumulative doses in routine radiological practice.

DiagnosticsVol. 15(13)
University of Debrecen (HU)
Massachusetts General Hospital
Good health and well-being
Openalex Percentile: Top 18%
Radiation Dose and Imaging
1.36
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.