The Effect of Implant Type Used in High Tibial Osteotomy on Tibial Slope Angle

Introduction: Knee osteoarthritis, marked by cartilage degeneration in the medial compartment, disrupts joint load balance and diminishes quality of life.Medial open-wedge high tibial osteotomy (MOWHTO) is a surgical procedure aimed at correcting these deformities.This study evaluates how different implant types used in MOWHTO affect the posterior tibial slope angle (PTSA), patellar height, and functional outcomes.Methods: Between 2017 and 2023, a retrospective study at Yeditepe University Kosuyolu Hospital analyzed 231 patients who underwent MOWHTO.Patients were categorized based on the implant type used: symmetric blocked plate (n=179), Puddu plate (n=26), and asymmetric blocked plate (n=26).The study evaluated pre-and postoperative parameters, including PTSA, hip-knee-ankle (HKA) angle, complication rates, and patient satisfaction.Statistical analyses involved paired t-tests for continuous variables, one-way ANOVA or Kruskal-Wallis tests for group comparisons, and chi-square tests for complication rates.The normality of data distribution was assessed using the Kolmogorov-Smirnov test for groups with n30 and the Shapiro-Wilk test for groups with n<30.Results: Postoperative changes in PTSA varied by implant type: the symmetric blocked plate group exhibited an average increase of +1.500.85, the Puddu plate group showed +1.901.10,and the asymmetric blocked plate group had a minimal change of +0.310.65.The mean operative time was 90.2312.5 minutes, and the average hospital stay was 3.020.9days.Patient satisfaction averaged 8.521.1 out of 10.Notably, the incidence of tibial plateau fractures was significantly higher in the asymmetric blocked plate group (15.38%, p=0.029).Discussion and Conclusion: Implant types can significantly affect PTSA and surgical outcomes after MOWHTO.All symmetrical plates showed similar PTSA changes, whereas this change was lower in the asymmetrical blocked plate group.Implant selection and surgical planning are critical for optimization of surgical outcomes.

Authors

Publication Details

Journal
Haydarpasa Numune Training and Research Hospital Medical Journal
Published
2025-01-01
DOI
https://doi.org/10.14744/hnhj.2025.01112
Primary Topic
Total Knee Arthroplasty Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Effect of Implant Type Used in High Tibial Osteotomy on Tibial Slope Angle

Ömer Yonga
Haydarpasa Numune Training and Research Hospital Medical Journal
Total Knee Arthroplasty Outcomes
article

The Effect of Implant Type Used in High Tibial Osteotomy on Tibial Slope Angle

Ömer Yonga
article en

Abstract

Introduction: Knee osteoarthritis, marked by cartilage degeneration in the medial compartment, disrupts joint load balance and diminishes quality of life.Medial open-wedge high tibial osteotomy (MOWHTO) is a surgical procedure aimed at correcting these deformities.This study evaluates how different implant types used in MOWHTO affect the posterior tibial slope angle (PTSA), patellar height, and functional outcomes.Methods: Between 2017 and 2023, a retrospective study at Yeditepe University Kosuyolu Hospital analyzed 231 patients who underwent MOWHTO.Patients were categorized based on the implant type used: symmetric blocked plate (n=179), Puddu plate (n=26), and asymmetric blocked plate (n=26).The study evaluated pre-and postoperative parameters, including PTSA, hip-knee-ankle (HKA) angle, complication rates, and patient satisfaction.Statistical analyses involved paired t-tests for continuous variables, one-way ANOVA or Kruskal-Wallis tests for group comparisons, and chi-square tests for complication rates.The normality of data distribution was assessed using the Kolmogorov-Smirnov test for groups with n30 and the Shapiro-Wilk test for groups with n<30.Results: Postoperative changes in PTSA varied by implant type: the symmetric blocked plate group exhibited an average increase of +1.500.85, the Puddu plate group showed +1.901.10,and the asymmetric blocked plate group had a minimal change of +0.310.65.The mean operative time was 90.2312.5 minutes, and the average hospital stay was 3.020.9days.Patient satisfaction averaged 8.521.1 out of 10.Notably, the incidence of tibial plateau fractures was significantly higher in the asymmetric blocked plate group (15.38%, p=0.029).Discussion and Conclusion: Implant types can significantly affect PTSA and surgical outcomes after MOWHTO.All symmetrical plates showed similar PTSA changes, whereas this change was lower in the asymmetrical blocked plate group.Implant selection and surgical planning are critical for optimization of surgical outcomes.

Haydarpasa Numune Training and Research Hospital Medical Journal
Openalex Percentile: Top 74%
Total Knee Arthroplasty Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

The Effect of Implant Type Used in High Tibial Osteotomy on Tibial Slope Angle — Ömer Yonga · Haydarpasa Numune Training and Research Hospital Medical Journal (2025) | TGRS Research Map | TGRS