IN VITRO EVALUATION OF MICROLEAKAGE AND SHEAR BOND STRENGTH OF SELF-ADHESIVE HYBRID COMPOSITES IN PRIMARY MOLARS

Introduction: Recently the self-adhesive hybrid composite, Surefil One™ was introduced as a “bioactive material”.Objectives: To assess microleakage and shear bond strength of Surefil One™ in comparison to Cention forte and resin-based composite used as restorations in primary molars.Methodology: 66 sound primary molars were randomly divided into two main groups (groups A and B). Each group was subdivided randomly into three equal subgroups. Groups (IA, IIA, and IIIA): were assigned to the microleakage evaluation test. A standardized box was prepared and restored with Surefil One™ (IA), Cention Forte (IIA) and Spectra™ ST HV (IIIA). Teeth were thermocycled, immersed into methylene blue solution for 24 hours, sectioned longitudinally, and examined under a stereomicroscope. Groups (IB, IIB, and IIIB): were assigned for the shear bond strength test. Surefil One™ (IB), Cention Forte (IIB) and Spectra™ ST HV (IIIB) were applied on the grounded buccal surface. A universal testing machine was used to assess the shear bond strength, and a stereomicroscope was used to evaluate mode of failure in each specimen. Kruskal Wallis test, One Way ANOVA were used to compare microleakage, shear bond strength respectively.Results: Penetration percentage was recorded in the Cention forte specimens (22.87%), followed by Spectra™ ST HV (50.00%), whereas Surefil One scored (65.71%) p < 0.0001. Cention forte samples showed shear bond strength (9.89 ±3.24 MPa), followed by Surefil One (4.57 ±1.98 MPa), then Spectra™ ST HV (4.47 ±2.20 MPa) p < 0.0001.Conclusion: Cention forte demonstrated less leakage and more retention than Spectra™ ST HV and Surefil One.

Authors

Institutions

Publication Details

Journal
Alexandria Dental Journal
Published
2025-06-17
DOI
https://doi.org/10.21608/adjalexu.2025.326823.1543
Primary Topic
Dental materials and restorations
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

IN VITRO EVALUATION OF MICROLEAKAGE AND SHEAR BOND STRENGTH OF SELF-ADHESIVE HYBRID COMPOSITES IN PRIMARY MOLARS

Azza Hanno, Safwat Mahmoud Abdelkader, Mahmoud Mohamed, sara Ibrahim Mohamed Zeitoun
2 links
Alexandria Dental Journal
Dental materials and restorations
article

IN VITRO EVALUATION OF MICROLEAKAGE AND SHEAR BOND STRENGTH OF SELF-ADHESIVE HYBRID COMPOSITES IN PRIMARY MOLARS

Azza Hanno, Safwat Mahmoud Abdelkader, Mahmoud Mohamed, sara Ibrahim Mohamed Zeitoun
article en

Abstract

Introduction: Recently the self-adhesive hybrid composite, Surefil One™ was introduced as a “bioactive material”.Objectives: To assess microleakage and shear bond strength of Surefil One™ in comparison to Cention forte and resin-based composite used as restorations in primary molars.Methodology: 66 sound primary molars were randomly divided into two main groups (groups A and B). Each group was subdivided randomly into three equal subgroups. Groups (IA, IIA, and IIIA): were assigned to the microleakage evaluation test. A standardized box was prepared and restored with Surefil One™ (IA), Cention Forte (IIA) and Spectra™ ST HV (IIIA). Teeth were thermocycled, immersed into methylene blue solution for 24 hours, sectioned longitudinally, and examined under a stereomicroscope. Groups (IB, IIB, and IIIB): were assigned for the shear bond strength test. Surefil One™ (IB), Cention Forte (IIB) and Spectra™ ST HV (IIIB) were applied on the grounded buccal surface. A universal testing machine was used to assess the shear bond strength, and a stereomicroscope was used to evaluate mode of failure in each specimen. Kruskal Wallis test, One Way ANOVA were used to compare microleakage, shear bond strength respectively.Results: Penetration percentage was recorded in the Cention forte specimens (22.87%), followed by Spectra™ ST HV (50.00%), whereas Surefil One scored (65.71%) p < 0.0001. Cention forte samples showed shear bond strength (9.89 ±3.24 MPa), followed by Surefil One (4.57 ±1.98 MPa), then Spectra™ ST HV (4.47 ±2.20 MPa) p < 0.0001.Conclusion: Cention forte demonstrated less leakage and more retention than Spectra™ ST HV and Surefil One.

Alexandria Dental JournalVol. 0(0)
Public Health Department (IN), Alexandria University (EG)
Openalex Percentile: Top 84%
Dental materials and restorations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.