Exploring the influence of air fractions on the performance of a vapor compression refrigeration system: an energy, exergy, and environmental analysis

Abstract The ingress of air into the vapor compression refrigeration system is a frequent occurrence, typically occurring during installation, maintenance, or charging. Air, being a non-condensable gas relative to the refrigerant gas within the system, leads to system degradation mostly due to elevated condensing pressure. This experimental study investigates the impact of non-condensable gas (air) contamination on the performance of a vapor compression refrigeration system using R134a refrigerant. A chest freezer was tested under steady-state conditions with air fractions of 0%, 1.7%, 2.5%, and 3.3% at an ambient temperature of 32 °C. Energy, exergy, and environmental analyses were conducted to evaluate system efficiency, power consumption, and sustainability. Results revealed that increasing air fractions significantly degraded performance: at 3.3% air, power consumption rose by 37.1%, while the coefficient of performance dropped by 42.8% compared to the air-free system. Also, exergy destruction rate increased by 189%, and exergy efficiency decreased by 119.1%, indicating severe thermodynamic inefficiencies. Additionally, higher air fractions led to elevated compressor temperatures, increased noise, and greater environmental impact due to higher energy-related emissions. The study highlights the critical need for rigorous system evacuation and leak prevention in refrigeration systems to maintain optimal efficiency and reduce operational costs.

Authors

Institutions

Publication Details

Journal
International Journal of Air-Conditioning and Refrigeration
Published
2025-06-30
DOI
https://doi.org/10.1007/s44189-025-00079-x
Citations
2
Primary Topic
Refrigeration and Air Conditioning Technologies
Type
article
Field-Weighted Citation Impact
1.43
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Exploring the influence of air fractions on the performance of a vapor compression refrigeration system: an energy, exergy, and environmental analysis

Saif Ali Kadhim, Mohammed Azeez Alomari, Hayder Mohsin Ali, Ali Habeeb Askar et al.
2 citations
International Journal of Air-Conditioning and Refrigeration
Refrigeration and Air Conditioning Technologies
1.43
article

Exploring the influence of air fractions on the performance of a vapor compression refrigeration system: an energy, exergy, and environmental analysis

Saif Ali Kadhim, Mohammed Azeez Alomari, Hayder Mohsin Ali, Ali Habeeb Askar, Ali M. Ashour, Ahmed M. Hassan, Karrar A. Hammoodi
article en
2 citations

Abstract

Abstract The ingress of air into the vapor compression refrigeration system is a frequent occurrence, typically occurring during installation, maintenance, or charging. Air, being a non-condensable gas relative to the refrigerant gas within the system, leads to system degradation mostly due to elevated condensing pressure. This experimental study investigates the impact of non-condensable gas (air) contamination on the performance of a vapor compression refrigeration system using R134a refrigerant. A chest freezer was tested under steady-state conditions with air fractions of 0%, 1.7%, 2.5%, and 3.3% at an ambient temperature of 32 °C. Energy, exergy, and environmental analyses were conducted to evaluate system efficiency, power consumption, and sustainability. Results revealed that increasing air fractions significantly degraded performance: at 3.3% air, power consumption rose by 37.1%, while the coefficient of performance dropped by 42.8% compared to the air-free system. Also, exergy destruction rate increased by 189%, and exergy efficiency decreased by 119.1%, indicating severe thermodynamic inefficiencies. Additionally, higher air fractions led to elevated compressor temperatures, increased noise, and greater environmental impact due to higher energy-related emissions. The study highlights the critical need for rigorous system evacuation and leak prevention in refrigeration systems to maintain optimal efficiency and reduce operational costs.

International Journal of Air-Conditioning and RefrigerationVol. 33(1)
University of Technology - Iraq (IQ), University of Miskolc (HU), University of Al Maarif (IQ), University of Al-Qadisiyah (IQ)
Openalex Percentile: Top 19%
Refrigeration and Air Conditioning Technologies
1.43
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.