Investigation of the radiation absorption parameters of dental Yttria-stabilized zirconium dioxide

Abstract Yttria stabilized zirconia (YSZ) is becoming increasingly popular in the field of dental biomaterial due to its faster production process, reduced preparation thickness, and lower cost. This study aims to compare the experimentally obtained gamma-ray absorption coefficients for YSZ dental biomaterial with theoretical data generated through GAMOS simulation and Phy-X/PSD software. The minimal µ value is determined to be 0.274 cm –1 at an energy of 1408 keV. The µ/ρ values for the 662 keV gamma ray, derived from experimental data, GAMOS simulation, and the Phy-X/PSD algorithm, are 0.070, 0.072, and 0.074 cm²/g, respectively. As gamma energy escalates, both the half-value layer and the tenth-value layer also increase. Comparable results are obtained from both the experimental data and the datasets generated by Phy-X/PSD and GAMOS. The mean free path value is measured to be 3.645 cm using 1408 keV photons. The experimentally obtained data show good agreement with the results obtained from the GAMOS simulation and the Phy-X/PSD program.

Authors

Institutions

Publication Details

Journal
Journal of the Australian Ceramic Society
Published
2025-06-30
DOI
https://doi.org/10.1007/s41779-025-01232-w
Citations
2
Primary Topic
Radiation Shielding Materials Analysis
Type
article
Field-Weighted Citation Impact
1.04
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Investigation of the radiation absorption parameters of dental Yttria-stabilized zirconium dioxide

Meryem Cansu Şahin, Emine Kayhan, Mehmet Kayhan
2 citations
Journal of the Australian Ceramic Society
Radiation Shielding Materials Analysis
1.04
article

Investigation of the radiation absorption parameters of dental Yttria-stabilized zirconium dioxide

Meryem Cansu Şahin, Emine Kayhan, Mehmet Kayhan
article en
2 citations

Abstract

Abstract Yttria stabilized zirconia (YSZ) is becoming increasingly popular in the field of dental biomaterial due to its faster production process, reduced preparation thickness, and lower cost. This study aims to compare the experimentally obtained gamma-ray absorption coefficients for YSZ dental biomaterial with theoretical data generated through GAMOS simulation and Phy-X/PSD software. The minimal µ value is determined to be 0.274 cm –1 at an energy of 1408 keV. The µ/ρ values for the 662 keV gamma ray, derived from experimental data, GAMOS simulation, and the Phy-X/PSD algorithm, are 0.070, 0.072, and 0.074 cm²/g, respectively. As gamma energy escalates, both the half-value layer and the tenth-value layer also increase. Comparable results are obtained from both the experimental data and the datasets generated by Phy-X/PSD and GAMOS. The mean free path value is measured to be 3.645 cm using 1408 keV photons. The experimentally obtained data show good agreement with the results obtained from the GAMOS simulation and the Phy-X/PSD program.

Journal of the Australian Ceramic SocietyVol. 61(4)
Usak University (TR)
Openalex Percentile: Top 24%
Radiation Shielding Materials Analysis
1.04
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.