To Investigate The Accuracy of Tube Selection According to Ultrasonographic Airway Measurements in Patients Undergoing OLV

To Investigate The Accuracy of Tube Selection According to Ultrasonographic Airway Measurements in Patients Undergoing OLVObjectives: Double-lumen endobronchial tubes (DLTs) are often used in one-lung ventilation (OLV).However, there is no optimal guide or parameter to estimate the accurate size of a DLT.The aim of this study was to investigate the role of ultrasonographic measurements-including tracheal width (TW), cricoid width (CW), lung offset, pulmonary pulse, and diaphragmatic motion-in selecting the correct DLT size.Methods: Thirty-four patients undergoing thoracic surgery requiring OLV were included in the study.In the selection of DLT size, a scale based on sonographic tracheal width (TW) and the patient's height was used.Sonographic lung measurements (SLM), including lung offset, pulmonary pulse, and diaphragmatic motion, were also used to confirm the location of the DLT, as compared to fiberoptic bronchoscopy (FOB).Results: The mean DLT size was 39 Fr, while the mean BCV was 2.5 mm.BCV was found to be suitable (successful intubation) in 29 patients (85.3%) and non-suitable (failed intubation) in 5 patients (14.7%).The three SLMs-lung shift, pulmonary pulse, and diaphragmatic movement-were 100% compatible with intubation and OLV. Conclusion:The sonographic TW-and height-based scale had an 85.3% success rate in determining the appropriate DLT size.Sonographic measurements of the lung were also found to be 100% compatible with intubation and OLV.Despite these promising results, sonographic measurements seem unlikely to replace FOB in DLT positioning.However, they may be helpful for selecting DLT size and confirming its placement, especially in the absence of FOB, in the presence of mucous plaque, or during emergency surgery.

Authors

Publication Details

Journal
JOURNAL OF CARDIO-VASCULAR-THORACIC ANAESTHESIA AND INTENSIVE CARE SOCIETY
Published
2025-01-01
DOI
https://doi.org/10.14744/gkdad.2025.96720
Primary Topic
Respiratory and Cough-Related Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

To Investigate The Accuracy of Tube Selection According to Ultrasonographic Airway Measurements in Patients Undergoing OLV

Yeliz Kılıç
JOURNAL OF CARDIO-VASCULAR-THORACIC ANAESTHESIA AND INTENSIVE CARE SOCIETY
Respiratory and Cough-Related Research
article

To Investigate The Accuracy of Tube Selection According to Ultrasonographic Airway Measurements in Patients Undergoing OLV

Yeliz Kılıç
article en

Abstract

To Investigate The Accuracy of Tube Selection According to Ultrasonographic Airway Measurements in Patients Undergoing OLVObjectives: Double-lumen endobronchial tubes (DLTs) are often used in one-lung ventilation (OLV).However, there is no optimal guide or parameter to estimate the accurate size of a DLT.The aim of this study was to investigate the role of ultrasonographic measurements-including tracheal width (TW), cricoid width (CW), lung offset, pulmonary pulse, and diaphragmatic motion-in selecting the correct DLT size.Methods: Thirty-four patients undergoing thoracic surgery requiring OLV were included in the study.In the selection of DLT size, a scale based on sonographic tracheal width (TW) and the patient's height was used.Sonographic lung measurements (SLM), including lung offset, pulmonary pulse, and diaphragmatic motion, were also used to confirm the location of the DLT, as compared to fiberoptic bronchoscopy (FOB).Results: The mean DLT size was 39 Fr, while the mean BCV was 2.5 mm.BCV was found to be suitable (successful intubation) in 29 patients (85.3%) and non-suitable (failed intubation) in 5 patients (14.7%).The three SLMs-lung shift, pulmonary pulse, and diaphragmatic movement-were 100% compatible with intubation and OLV. Conclusion:The sonographic TW-and height-based scale had an 85.3% success rate in determining the appropriate DLT size.Sonographic measurements of the lung were also found to be 100% compatible with intubation and OLV.Despite these promising results, sonographic measurements seem unlikely to replace FOB in DLT positioning.However, they may be helpful for selecting DLT size and confirming its placement, especially in the absence of FOB, in the presence of mucous plaque, or during emergency surgery.

JOURNAL OF CARDIO-VASCULAR-THORACIC ANAESTHESIA AND INTENSIVE CARE SOCIETY
Openalex Percentile: Top 75%
Respiratory and Cough-Related Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.