Immunalysis tapentadol assay reformulation resolves tramadol interference

This study evaluated the performance of the Immunalysis Tapentadol 343 Urine Enzyme Immunoassay (EIA) screening kit, focusing on the prevalence of false-positive results due to cross-reactivity with tramadol. Tapentadol is a dual-action analgesic, modulating μ-opioid receptors and inhibiting norepinephrine reuptake, while tramadol, a structurally related compound, is a weak μ-opioid receptor agonist and norepinephrine/serotonin reuptake inhibitor. Cross-reactivity between these compounds can complicate urine drug screening results for adherence monitoring in chronic pain management. A total of 28 samples initially produced false-positive results for tapentadol BNl using the Immunalysis Tapentadol 343 Urine EIA screening kit. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) was used to confirm the absence of tapentadol. Of the false-positive samples, 61% contained tramadol at concentrations below the manufacturer-reported cross-reactivity threshold of 60 000 ng/mL, indicating assay limitations in specificity. To address this issue, a newly reformulated Immunalysis Tapentadol 343UR Urine HEIA kit was evaluated for tramadol cross-reactivity. Upon retesting the 28 false-positive samples with the reformulated kit, no false positives were detected, with results consistent with LC-MS/MS confirmation. The rate of false-positive tapentadol screens in urine has substantially reduced since the implementation of the new tapentadol kit in routine testing. These findings demonstrate the importance of assay verification to assess cross-reactivity, particularly for structurally related compounds. The reformulated Immunalysis Tapentadol 343UR kit shows improved specificity, reducing false-positive rates and enhancing the accuracy of tapentadol detection in clinical and forensic toxicology applications.

Authors

Institutions

Publication Details

Journal
Journal of Analytical Toxicology
Published
2025-06-29
DOI
https://doi.org/10.1093/jat/bkaf060
Primary Topic
Forensic Toxicology and Drug Analysis
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Immunalysis tapentadol assay reformulation resolves tramadol interference

Sonia L. La’ulu, Alun Conrad Jackson, Jessica M. Boyd, Kamisha L. Johnson‐Davis et al.
1 links
Journal of Analytical Toxicology
Forensic Toxicology and Drug Analysis
article

Immunalysis tapentadol assay reformulation resolves tramadol interference

Sonia L. La’ulu, Alun Conrad Jackson, Jessica M. Boyd, Kamisha L. Johnson‐Davis, Adeolu Adegoke, Joseph W. Rudolf, Charles A. Anderson
article en

Abstract

This study evaluated the performance of the Immunalysis Tapentadol 343 Urine Enzyme Immunoassay (EIA) screening kit, focusing on the prevalence of false-positive results due to cross-reactivity with tramadol. Tapentadol is a dual-action analgesic, modulating μ-opioid receptors and inhibiting norepinephrine reuptake, while tramadol, a structurally related compound, is a weak μ-opioid receptor agonist and norepinephrine/serotonin reuptake inhibitor. Cross-reactivity between these compounds can complicate urine drug screening results for adherence monitoring in chronic pain management. A total of 28 samples initially produced false-positive results for tapentadol BNl using the Immunalysis Tapentadol 343 Urine EIA screening kit. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) was used to confirm the absence of tapentadol. Of the false-positive samples, 61% contained tramadol at concentrations below the manufacturer-reported cross-reactivity threshold of 60 000 ng/mL, indicating assay limitations in specificity. To address this issue, a newly reformulated Immunalysis Tapentadol 343UR Urine HEIA kit was evaluated for tramadol cross-reactivity. Upon retesting the 28 false-positive samples with the reformulated kit, no false positives were detected, with results consistent with LC-MS/MS confirmation. The rate of false-positive tapentadol screens in urine has substantially reduced since the implementation of the new tapentadol kit in routine testing. These findings demonstrate the importance of assay verification to assess cross-reactivity, particularly for structurally related compounds. The reformulated Immunalysis Tapentadol 343UR kit shows improved specificity, reducing false-positive rates and enhancing the accuracy of tapentadol detection in clinical and forensic toxicology applications.

Journal of Analytical ToxicologyVol. 49(9)
University of Utah (US), ARUP Laboratories (United States) (US), Utah Department of Health (US), ARUP Institute for Clinical and Experimental Pathology, ARUP Laboratories (United States) (US)
ARUP Institute for Clinical and Experimental Pathology, ARUP Laboratories
Good health and well-being
Openalex Percentile: Top 85%
Forensic Toxicology and Drug Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.