Portable and Rapid Smartphone-Based Colorimetric Assay of Peracetic Acid for Point-of-Use Medical/Pharmaceutical Disinfectant Preparation

A simple and rapid smartphone-based colorimetric assay for peracetic acid concentration was developed to facilitate point-of-use disinfectant preparations for infection prevention and control. The colorimetric detection was based on the oxidation of N,N-diethyl-phenylenediamine by peracetic acid through an intermediate reaction with potassium iodide, resulting in pink-magenta products. The colorimetric reaction was performed on a 96-well plate; then, the color products were photographed in one image. The color intensity was evaluated to determine the peracetic acid concentration using a custom-built mobile application named Modern Peracetic Acid Analysis. The relative green intensity of the pink-magenta products was directly proportional to the peracetic acid concentration in the range of 0.15 to 3.0 µg/mL. The detection and quantitation limits were 0.11 µg/mL and 0.34 µg/mL, respectively. The approach was successfully applied to determine the peracetic acid concentration in pharmaceutical disinfectant formulations. The results obtained using the proposed approach showed no significant differences from those obtained using acid-base titration at the 95% confidence level. The greenness of the proposed approach was evaluated using the Complementary Green Analytical Procedure Index, Analytical Greenness, and Blue Applicability Grade Index, demonstrating enhanced environmental friendliness and practical advantages, as well as simple, portable instrumentation that is easier to operate than traditional spectrophotometric and titration methods. Furthermore, a sustainability assessment based on the Need, Quality, and Sustainability index underscored its enhanced sustainability.

Authors

Institutions

Publication Details

Journal
Molecules
Published
2025-06-28
DOI
https://doi.org/10.3390/molecules30132798
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Portable and Rapid Smartphone-Based Colorimetric Assay of Peracetic Acid for Point-of-Use Medical/Pharmaceutical Disinfectant Preparation

Naohito Kawasaki, Chalermpong Saenjum, Busaban Sirithunyalug, Fumihiko Ogata et al.
Molecules
Biosensors and Analytical Detection
article

Portable and Rapid Smartphone-Based Colorimetric Assay of Peracetic Acid for Point-of-Use Medical/Pharmaceutical Disinfectant Preparation

Naohito Kawasaki, Chalermpong Saenjum, Busaban Sirithunyalug, Fumihiko Ogata, Jutamas Jiaranaikulwanitch, Sutasinee Apichai, Kate Grudpan, Suphakorn Katib
article en

Abstract

A simple and rapid smartphone-based colorimetric assay for peracetic acid concentration was developed to facilitate point-of-use disinfectant preparations for infection prevention and control. The colorimetric detection was based on the oxidation of N,N-diethyl-phenylenediamine by peracetic acid through an intermediate reaction with potassium iodide, resulting in pink-magenta products. The colorimetric reaction was performed on a 96-well plate; then, the color products were photographed in one image. The color intensity was evaluated to determine the peracetic acid concentration using a custom-built mobile application named Modern Peracetic Acid Analysis. The relative green intensity of the pink-magenta products was directly proportional to the peracetic acid concentration in the range of 0.15 to 3.0 µg/mL. The detection and quantitation limits were 0.11 µg/mL and 0.34 µg/mL, respectively. The approach was successfully applied to determine the peracetic acid concentration in pharmaceutical disinfectant formulations. The results obtained using the proposed approach showed no significant differences from those obtained using acid-base titration at the 95% confidence level. The greenness of the proposed approach was evaluated using the Complementary Green Analytical Procedure Index, Analytical Greenness, and Blue Applicability Grade Index, demonstrating enhanced environmental friendliness and practical advantages, as well as simple, portable instrumentation that is easier to operate than traditional spectrophotometric and titration methods. Furthermore, a sustainability assessment based on the Need, Quality, and Sustainability index underscored its enhanced sustainability.

MoleculesVol. 30(13)
Chiang Mai University (TH), Kindai University (JP)
Chiang Mai University, National Research Council of Thailand, Royal Golden Jubilee (RGJ) Ph.D. Programme
Responsible consumption and production, Life in Land
Openalex Percentile: Top 86%
Biosensors and Analytical Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.