Hygiene Efficacy of Short Cycles in Domestic Dishwashers

This study investigated how factors associated with Sinner's principle-namely temperature, time, and the chemical composition of detergents-affected the antimicrobial efficacy of domestic dishwashers, particularly during short cycles. These are of particular interest, because many consumers refrain from using long cycles while it is still unclear if short cycles can provide a sufficient level of hygiene. Thus, we chose a range of bacterial strains, including standard test strains such as <i>Micrococcus luteus</i> and <i>Enterococcus faecium</i>, as well as important foodborne pathogens such as <i>Escherichia coli</i>, <i>Staphylococcus aureus</i>, and Salmonella enterica. To account for the complexity of dishwasher cycles, we correlated hygiene efficacy with area under the curve (AUC) measurements derived from the respective cycle profiles. Our findings revealed that the reductions in <i>M. luteus</i> and <i>E. faecium</i> were minimally affected by the reference detergent. In contrast, a high-tier market detergent demonstrated a significant decrease in bacterial counts. Notably, both strains exhibited reduced efficacy at a main cycle temperature of 45 °C, suggesting that temperatures below 50 °C might represent a critical threshold at which the hygiene efficacy of domestic dishwashing processes declines. However, since food-related pathogens were more susceptible to the dishwashing process, even lower temperatures might deliver a sufficient level of hygiene. Plotting the logarithmic reduction/AUC ratio against the AUC indicated that the main cycle contributed approximately 10-fold more to microbial reduction than the rinse cycle. Furthermore, the antimicrobial impact of detergents was greatest at the lowest AUC values (i.e., during short cycles). Taken together, our results suggest that the applied chemistry may help to enhance antimicrobial performance especially in short dishwashing cycles.

Authors

Institutions

Publication Details

Journal
Microorganisms
Published
2025-06-30
DOI
https://doi.org/10.3390/microorganisms13071542
Primary Topic
Food Safety and Hygiene
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Hygiene Efficacy of Short Cycles in Domestic Dishwashers

Dirk P. Bockmühl, Thomas J. Tewes, Laurence Harcq, Emma Gibbin-Lameira et al.
Microorganisms
Food Safety and Hygiene
article

Hygiene Efficacy of Short Cycles in Domestic Dishwashers

Dirk P. Bockmühl, Thomas J. Tewes, Laurence Harcq, Emma Gibbin-Lameira, Matthias Kudla
article en

Abstract

This study investigated how factors associated with Sinner's principle-namely temperature, time, and the chemical composition of detergents-affected the antimicrobial efficacy of domestic dishwashers, particularly during short cycles. These are of particular interest, because many consumers refrain from using long cycles while it is still unclear if short cycles can provide a sufficient level of hygiene. Thus, we chose a range of bacterial strains, including standard test strains such as <i>Micrococcus luteus</i> and <i>Enterococcus faecium</i>, as well as important foodborne pathogens such as <i>Escherichia coli</i>, <i>Staphylococcus aureus</i>, and Salmonella enterica. To account for the complexity of dishwasher cycles, we correlated hygiene efficacy with area under the curve (AUC) measurements derived from the respective cycle profiles. Our findings revealed that the reductions in <i>M. luteus</i> and <i>E. faecium</i> were minimally affected by the reference detergent. In contrast, a high-tier market detergent demonstrated a significant decrease in bacterial counts. Notably, both strains exhibited reduced efficacy at a main cycle temperature of 45 °C, suggesting that temperatures below 50 °C might represent a critical threshold at which the hygiene efficacy of domestic dishwashing processes declines. However, since food-related pathogens were more susceptible to the dishwashing process, even lower temperatures might deliver a sufficient level of hygiene. Plotting the logarithmic reduction/AUC ratio against the AUC indicated that the main cycle contributed approximately 10-fold more to microbial reduction than the rinse cycle. Furthermore, the antimicrobial impact of detergents was greatest at the lowest AUC values (i.e., during short cycles). Taken together, our results suggest that the applied chemistry may help to enhance antimicrobial performance especially in short dishwashing cycles.

MicroorganismsVol. 13(7)
Procter & Gamble (Belgium) (BE), Rhine-Waal University of Applied Sciences (DE)
Zero hunger
Openalex Percentile: Top 82%
Food Safety and Hygiene
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.