Identification of the Parameters of the Szpica–Warakomski Method’s Rectilinear Trend Complementary to the Gaussian Characteristic Area Method in the Functional Evaluation of Gas Injectors

The Fit for 55 and Euro 7 regulations significantly reduce CO<sub>2</sub> emissions from combustion sources. This will be reflected in the regulations governing the approval of in-service vehicles, including those using alternative fuels. The present study focused on the rapid diagnostics of the technical condition of gas injectors. The test method was a modification of the Gaussian characteristic fields method using the Szpica-Warakomski rectilinear trend. The flow tests resulted in average volumetric intensities of 111 NL/min and 124 NL/min, depending on the operating conditions. The opening and closing times were in the range of (1.3…3.5) ms. The directional parameter of the rectilinear trend, which is important from the point of view of the analyses, was 0.97 for brand new (BN) injectors and 1.00 for in-service (IO) injectors. The intersection parameters were 0.64 and 0.24, respectively. The qualitative evaluation yielded coefficients of determination of 95.01 and 94.07. The values of the trend parameters were strongly dependent on the design solution and model/type of injector. Inferring the effect of operating condition on the trend parameter values, a one-factor analysis of variance was performed, which showed the significance of only the directional coefficient. A comparison of the same BN and IO injector model showed an apparent change in the value of the intercept only. No significant relationships between the injector opening and closing times and the trend parameters were shown. Thus, the usefulness of using the Szpica-Warakomski rectilinear trend in the functional evaluation of gas injectors of different designs and under different operating conditions was demonstrated.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2025-06-27
DOI
https://doi.org/10.3390/s25134020
Primary Topic
Advanced Combustion Engine Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Identification of the Parameters of the Szpica–Warakomski Method’s Rectilinear Trend Complementary to the Gaussian Characteristic Area Method in the Functional Evaluation of Gas Injectors

Andrzej Borawski, Paweł Woś, Jacek Hunicz, B. Ashok et al.
Sensors
Advanced Combustion Engine Technologies
article

Identification of the Parameters of the Szpica–Warakomski Method’s Rectilinear Trend Complementary to the Gaussian Characteristic Area Method in the Functional Evaluation of Gas Injectors

Andrzej Borawski, Paweł Woś, Jacek Hunicz, B. Ashok, Grzegorz Mieczkowski, Dariusz Szpica
article en

Abstract

The Fit for 55 and Euro 7 regulations significantly reduce CO<sub>2</sub> emissions from combustion sources. This will be reflected in the regulations governing the approval of in-service vehicles, including those using alternative fuels. The present study focused on the rapid diagnostics of the technical condition of gas injectors. The test method was a modification of the Gaussian characteristic fields method using the Szpica-Warakomski rectilinear trend. The flow tests resulted in average volumetric intensities of 111 NL/min and 124 NL/min, depending on the operating conditions. The opening and closing times were in the range of (1.3…3.5) ms. The directional parameter of the rectilinear trend, which is important from the point of view of the analyses, was 0.97 for brand new (BN) injectors and 1.00 for in-service (IO) injectors. The intersection parameters were 0.64 and 0.24, respectively. The qualitative evaluation yielded coefficients of determination of 95.01 and 94.07. The values of the trend parameters were strongly dependent on the design solution and model/type of injector. Inferring the effect of operating condition on the trend parameter values, a one-factor analysis of variance was performed, which showed the significance of only the directional coefficient. A comparison of the same BN and IO injector model showed an apparent change in the value of the intercept only. No significant relationships between the injector opening and closing times and the trend parameters were shown. Thus, the usefulness of using the Szpica-Warakomski rectilinear trend in the functional evaluation of gas injectors of different designs and under different operating conditions was demonstrated.

SensorsVol. 25(13)
Rzeszów University of Technology (PL), Bialystok University of Technology (PL), Lublin University of Technology (PL), Vellore Institute of Technology University (IN)
Openalex Percentile: Top 87%
Advanced Combustion Engine Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies