Insulator Partial Discharge Localization Based on Improved Wavelet Packet Threshold Denoising and Gxx−β Generalized Cross-Correlation Algorithm

Partial discharge (PD) in insulators will not only lead to the gradual degradation of insulation performance but even cause power system failure in serious cases. Because there is strong noise interference in the field, it is difficult to accurately locate the position of the PD source. Therefore, this paper proposes a three-dimensional spatial localization method of the PD source with a four-element ultra-high-frequency (UHF) array based on improved wavelet packet dynamic threshold denoising and the Gxx-β generalized cross-correlation algorithm. Firstly, considering the field noise interference, the PD signal is decomposed into sub-signals with different frequency bands by the wavelet packet, and the corresponding wavelet packet coefficients are extracted. By using the improved threshold function to process the wavelet packet coefficients, the PD signal with low distortion rate and high signal-to-noise ratio (SNR) is reconstructed. Secondly, in order to solve the problem that the amplitude of the first wave of the PD signal is small and the SNR is low, an improved weighting function, Gxx-β, is proposed, which is based on the self-power spectral density of the signal and is adjusted by introducing an exponential factor to improve the accuracy of the first wave arrival time and time difference calculation. Finally, the influence of different sensor array shapes and PD source positions on the localization results is analyzed, and a reasonable arrangement scheme is found. In order to verify the performance of the proposed method, simulation and experimental analysis are carried out. The results show that the improved wavelet packet denoising algorithm can effectively realize the separation of PD signal and noise and improve the SNR of the localization signal with low distortion rate. The improved Gxx-β weighting function significantly improves the estimation accuracy of the time difference between UHF sensors. With the sensor array designed in this paper, the relative localization error is 3.46%, and the absolute error is within 6 cm, which meets the requirements of engineering applications.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2025-06-30
DOI
https://doi.org/10.3390/s25134089
Primary Topic
High voltage insulation and dielectric phenomena
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Insulator Partial Discharge Localization Based on Improved Wavelet Packet Threshold Denoising and Gxx−β Generalized Cross-Correlation Algorithm

Hongxin Ji, Xinghua Liu, Zijian Tang, Chao Zheng
Sensors
High voltage insulation and dielectric phenomena
article

Insulator Partial Discharge Localization Based on Improved Wavelet Packet Threshold Denoising and Gxx−β Generalized Cross-Correlation Algorithm

Hongxin Ji, Xinghua Liu, Zijian Tang, Chao Zheng
article en

Abstract

Partial discharge (PD) in insulators will not only lead to the gradual degradation of insulation performance but even cause power system failure in serious cases. Because there is strong noise interference in the field, it is difficult to accurately locate the position of the PD source. Therefore, this paper proposes a three-dimensional spatial localization method of the PD source with a four-element ultra-high-frequency (UHF) array based on improved wavelet packet dynamic threshold denoising and the Gxx-β generalized cross-correlation algorithm. Firstly, considering the field noise interference, the PD signal is decomposed into sub-signals with different frequency bands by the wavelet packet, and the corresponding wavelet packet coefficients are extracted. By using the improved threshold function to process the wavelet packet coefficients, the PD signal with low distortion rate and high signal-to-noise ratio (SNR) is reconstructed. Secondly, in order to solve the problem that the amplitude of the first wave of the PD signal is small and the SNR is low, an improved weighting function, Gxx-β, is proposed, which is based on the self-power spectral density of the signal and is adjusted by introducing an exponential factor to improve the accuracy of the first wave arrival time and time difference calculation. Finally, the influence of different sensor array shapes and PD source positions on the localization results is analyzed, and a reasonable arrangement scheme is found. In order to verify the performance of the proposed method, simulation and experimental analysis are carried out. The results show that the improved wavelet packet denoising algorithm can effectively realize the separation of PD signal and noise and improve the SNR of the localization signal with low distortion rate. The improved Gxx-β weighting function significantly improves the estimation accuracy of the time difference between UHF sensors. With the sensor array designed in this paper, the relative localization error is 3.46%, and the absolute error is within 6 cm, which meets the requirements of engineering applications.

SensorsVol. 25(13)
China University of Mining and Technology (CN), Tianjin Research Institute of Electric Science (China) (CN), Shandong Agricultural University (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 89%
High voltage insulation and dielectric phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.