Study on the Electromagnetic Characteristics of a Twin Inverter System EV Traction Motor Under Various Operating Conditions

This paper analyzes the electromagnetic characteristics of an interior permanent magnet synchronous motor (IPMSM) for electric vehicle traction under various control imbalance conditions in a twin inverter system, assuming that one of the inverters fails to operate properly. The imbalance conditions are first investigated through dynamometer experiments and then applied to finite element method (FEM) simulations to evaluate their electromagnetic effects. Since the focus is on scenarios where a single inverter malfunctions, a stator winding configuration is first redefined to ensure stable operation in a single inverter system by preventing voltage and current imbalances within the circuit. When the stator winding is configured with eight parallel paths, the dynamometer test results show a phase voltage imbalance. However, when the number of parallel circuits is reduced to four, this voltage imbalance disappears. Using this configuration, a twin inverter system is constructed, and various imbalance conditions are applied to intuitively examine the electromagnetic characteristics when one inverter fails to accurately control current magnitude or phase angle. The simulation results showed that applying unbalanced conditions to the current and current phase angle led to a decrease in torque and an increase in torque ripple. In addition, when one of the inverters was completely disconnected, the motor performance analysis showed that it operated with approximately half of its original performance. Based on dynamometer experiments and finite element method (FEM) simulations, the electromagnetic characteristics under inverter fault conditions and appropriate stator winding configurations were analyzed. When an optimal number of parallel circuits is applied to the stator winding and a twin inverter system is employed, the load on each individual inverter is reduced, enabling accurate control. This makes the application to high-voltage and high-current systems feasible, allowing higher performance. Moreover, even if one inverter fails, the system can still operate at approximately half its capacity, ensuring high operational reliability.

Authors

Institutions

Publication Details

Journal
Energies
Published
2025-06-29
DOI
https://doi.org/10.3390/en18133415
Primary Topic
Multilevel Inverters and Converters
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study on the Electromagnetic Characteristics of a Twin Inverter System EV Traction Motor Under Various Operating Conditions

Ki-Chan Kim, Hong–Jae Jang, Taesu Kim, Jongmin Shin
Energies
Multilevel Inverters and Converters
article

Study on the Electromagnetic Characteristics of a Twin Inverter System EV Traction Motor Under Various Operating Conditions

Ki-Chan Kim, Hong–Jae Jang, Taesu Kim, Jongmin Shin
article en

Abstract

This paper analyzes the electromagnetic characteristics of an interior permanent magnet synchronous motor (IPMSM) for electric vehicle traction under various control imbalance conditions in a twin inverter system, assuming that one of the inverters fails to operate properly. The imbalance conditions are first investigated through dynamometer experiments and then applied to finite element method (FEM) simulations to evaluate their electromagnetic effects. Since the focus is on scenarios where a single inverter malfunctions, a stator winding configuration is first redefined to ensure stable operation in a single inverter system by preventing voltage and current imbalances within the circuit. When the stator winding is configured with eight parallel paths, the dynamometer test results show a phase voltage imbalance. However, when the number of parallel circuits is reduced to four, this voltage imbalance disappears. Using this configuration, a twin inverter system is constructed, and various imbalance conditions are applied to intuitively examine the electromagnetic characteristics when one inverter fails to accurately control current magnitude or phase angle. The simulation results showed that applying unbalanced conditions to the current and current phase angle led to a decrease in torque and an increase in torque ripple. In addition, when one of the inverters was completely disconnected, the motor performance analysis showed that it operated with approximately half of its original performance. Based on dynamometer experiments and finite element method (FEM) simulations, the electromagnetic characteristics under inverter fault conditions and appropriate stator winding configurations were analyzed. When an optimal number of parallel circuits is applied to the stator winding and a twin inverter system is employed, the load on each individual inverter is reduced, enabling accurate control. This makes the application to high-voltage and high-current systems feasible, allowing higher performance. Moreover, even if one inverter fails, the system can still operate at approximately half its capacity, ensuring high operational reliability.

EnergiesVol. 18(13)
Hanbat National University (KR), Daewon Pharm (South Korea) (KR)
Ministry of Trade, Industry and Energy, Wake Forest School of Medicine
Openalex Percentile: Top 86%
Multilevel Inverters and Converters
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.